SONIC DIGITAL HS - ultrasonic generators

SONIC DIGITAL HS TD/SD - 22604 Assignment of the 15-pole DSUB interface socket

www.weber-ultrasonics.com PIN No. on DSUB SOCKETInterfaceSignal nameDescription1+15 VOLT OUT15 Volt for external use2POUTOutput 0 – 10 Volt = Power output 0 – 100% 3P-EXT.-INInput 5 – 10 Volt for power control 4GNDShared reference point = Ground 5/9HF-DA-ERRORRelay root (shared) for “HF-DA” and “ERROR” 6HF-DARelay output “HF-DA”7ERRORRelay output “ERROR”8NCNot assigned! Do not connect! 9/5HF-DA-ERRORRelay root (shared) for „HF-DA” and „ERROR” 10NCNot assigned! Do not connect! 11 Nominal Output for nominal value 12FAN-ONMonitoring output = 12 Volt when the fan is running 13FS-24VRemote control input (with 15 – 24 Volt) 14FS -GNDRemote control input (to GND) 15GNDShared reference point = Ground

ATTENTION: A shielded control cable must always be used for the interface.