4120A S100 S110/xx + 402x.1x S100
3Pages

{{requestButtons}}

Catalog excerpts

4120A S100 S110/xx + 402x.1x S100 - 1

Flow switch for liquid media The flow-captor type 4120A S100 Sl10/xx + 402x.1x S100 is a separate system consisting of sensor and electronics. The sensor is used in automation processes where liquid media have to be controlled or monitored. The electronic sensor works according to the calorimetric measuring principle and without any mechanically moved parts. The sensor detects the flow velocity of the medium and converts it into an electrical signal. • for medium temperature up to max. 140 °C / 284 °F (S100) • extended sensor, 20 - 90 mm (S110/xx) • pressure resistant up to 100 bar • defined switching signal • temperature-independent • robust design: fully encapsulated sensor and electronics • ISO 9001:2015 Technical data Type Medium Sensor data Measuring range Set-point range Pressure Response time Linearity deviation Repeatability tolerance Hysteresis Temperaturdrift Mechanical data Protection class sensor Protection class electronics Material: housing Material: sensor probe Sensor probe sizes approx. 15 % - 90 % of range setting max. 100 bar (1450 PSI) 2 sec. - 10 sec. depending on range setting 2 sec. - 15 sec. depending on range setting < 5 % *1 < 5 % *2 < 2 % approx. 10 % < 0.3 % K IP67 IP65 ABS stainless steel AISI 316Ti (other material on request) a) flow-captor 4120 / W" BSP Length 20 mm, W BSP b) flow-captor 4120 / y2" BSP Length 30 mm, y" BSP c) flow-captor 4120 / y2" BSP S110/45 Length 45 mm, y" BSP d) flow-captor 4120 / y2" BSP S110/67 Length 67 mm, y2" BSP e) flow-captor 4120 / y2" BSP S110/90 Length 90 mm, y2" BSP screw terminal block H120 x B80 X T56 (drawing K70031) 18 to 30 VDC, incl. residual ripple max. 150 mA (pulsed) approx. 1 W < 400 mA reverse polarity, short circuit and overload reverse < 2.5 V at max. load approx. 10 sec. after connection of power 4020.12 PNP n.c. (opener) energized at zero flow 4021.12 PNP n.c. (opener) energized at zero flow 4020.13 PNP n.o. (closer) currentless at zero flow 4021.13 PNP n.o. (closer) currentless at zero flow *1 bezogen auf Wasser *2 bezogen auf „Shell Diala S4 ZX-I“ Electrical connection Body dimensions Electrical data Operating voltage Current consumption Power consumption Switching current Circuit protection Voltage drop Initial operation Electrical output weber Sensors GmbH Strohdeich 32 Sensors Ltd. 66 Eastbourne Road, Southport Sensors LLC. 4462 Bretton Court, Building 1, Suite 7 www.captor.de info@captor.de sales@captor.co.uk sales@captor.com Technical data subject to alteration! Rev. AA 25.05.18

Open the catalog to page 1
4120A S100 S110/xx + 402x.1x S100 - 2

Temperature data Type Medium temperature in relation to ambient temperature weber Sensors GmbH Strohdeich 32 Sensors Ltd. 66 Eastbourne Road, Southport Sensors LLC. 4462 Bretton Court, Building 1, Suite 7 www.captor.de info@captor.de sales@captor.co.uk sales@captor.com Technical data subject to alteration! Rev. AA

Open the catalog to page 2
4120A S100 S110/xx + 402x.1x S100 - 3

Gehause HxBxT Housing H x W x D 120 x 80 x 56

Open the catalog to page 3

All Weber Sensors GmbH catalogs and technical brochures

  1. PAX DP

    1 Pages

  2. foto-captor

    2 Pages

  3. foto-captor

    2 Pages