Ultrasonic Distance Sensor UPT
5Pages

{{requestButtons}}

Catalog excerpts

Ultrasonic Distance Sensor UPT - 1

Content: Technical Data Technical Drawing Teach-in Guide Electrical Connection Sound Cones Order Code Series UPT Key-Features: - Available measurement ranges from 400 to 3500 mm - Repeatability up to 0.5 mm ...2 - Linearity < 0.5 % of full scale ...2 - Ultrasonic distance sensor or 2 point proximity ...4 - Rectangular housing with small dimensions ...5 - Teachable measurement range ...5 - Measurement is independent of the targets material, surface, colour or transparency - Protection class up to IP67

Open the catalog to page 1
Ultrasonic Distance Sensor UPT - 2

TECHNICAL DATA UPT-400 Detection range Repeatability Linearity Resolution Inverted characteristic curve Control inputs Safety features Temperature range Protection against reverse polarity and short circuit [°C] Connection Dimensions Housing material Protection class Angle of the sound cone Distance sensor Response time Signal output Current consumption (no load) Power supply 2 point proximity switch Response time Signal output Hysteresis Max. output current Adjustment of switching points Current consumption (no load) Power supply TECHNICAL DRAWING

Open the catalog to page 2
Ultrasonic Distance Sensor UPT - 3

TEACH-IN GUIDE 2 POINT PROXIMITY SWITCH 2 point proximity switch (teach-In) 3 different modes of switching outputs can be selected with this sensor - Normal switching function - Window function - Adjustable hysteresis All these functions are selected by using the Teach key. Each mode has a different sequence using the Echo, P1 and P2 LEDs. The different steps are shown in the diagram on the right. Functions of the sensors control devices: EC (Echo LED): P1 LED: P2 LED: ON LED: Teach Key (TK): is on, when an echo is received (alignment LED). Status of the switching output SP1 Status of the...

Open the catalog to page 3
Ultrasonic Distance Sensor UPT - 4

Functions of the sensors control devices: is on, if an echo is received (alignment LED). either P1 or P2 is On if there is no object between P1 and P2. On if the sensor is connected to power supply Button (total teach in time approx. 30 sec.) Positive slope: P1<P2 Negative slope: P2<P1 Teach Mode P1 (Position 0 V, respectively 4 mA) 1. Press Teach-Key (approx. 6 sec.) until EC (Echo LED) and P1 are blinking with a 2 Hz frequency. The sensor is now in Teach Modus P1. 2. Release Teach-Key: now P1 blinks with a 1 Hz frequency and EC LED is in function (alignment LED). There is a time window of...

Open the catalog to page 4
Ultrasonic Distance Sensor UPT - 5

SOUND CONE GEOMETRY The exact geometry of the sound cone depends on the air-pressure, temperature, humidity and size of the target. connector output, 5 pole Output 0 … 10 V 4 … 20 mA Switching output (2 x PNP) Switching output (2 x NPN) on request Warning, Safety Information These devices are not designed for critical safety or emergency shut-down purposes. Therefore they should never be used in an application, where a malfunction of the device could cause personal injury. Subject to change without prior notice. WayCon Positionsmesstechnik GmbH E-Mail: info@waycon.de Internet: www.waycon.de

Open the catalog to page 5