SX300 Hydraulic transducer
8Pages

{{requestButtons}}

Catalog excerpts

SX300 Hydraulic transducer - 1

Content: Introduction Technical Data Technical Drawing Installation Accessories Order Code Series SX300 Key-Features: - Measurement range up to 15 m - Pressure-sealed up to 300 bar 2 - Output signals: SSI, CANopen, Profibus, EtherCAT, 3 Profinet, further on request 4 - Alternative draw wire mechanics for encoder

Open the catalog to page 1
SX300 Hydraulic transducer - 2

INTRODUCTION The Draw Wire Series SX300 by WayCon is designed for use in combination with hydraulic cylinders and measuring the cylinder position. Especially designed for long stroke cylinders with pressurized housings to be flanged directly to the cylinder head. By giving feedback signals to a machine control unit, it is possible to control the position of a cylinder, to program specific movements or to manage synchronous movements of several cylinders. Due to its small overall size, its short assembly time and its possible customisation, this sensor technology is a cost-effective and...

Open the catalog to page 2
SX300 Hydraulic transducer - 3

TECHNICAL DATA MECHANIC Measurement range Linearity ±0.05 (depending on the used encoder) Sheave circumference Operating temperature Hydraulic fluid only non-hazardous fluids (non-flammable, non-toxic), no gaseous media Operating pressure Testing pressure Pressure port Piston travel speed Rope tension Wire sag (calculated) start of measurement range: 10...11.5 (13...16.5) end of measurement range: 29...31.5 (37...43) Connector orientation Weight Draw wire Encoder requirements stainless steel 1.4301, Ø 0.69 mm flange with stator coupling Ø 58 pitch circle diameter for fixing screws 63 hollow...

Open the catalog to page 3
SX300 Hydraulic transducer - 4

TECHNICAL DRAWING Flange type F1 (rod sealing) 196,5 SCREWED SEALING PLUG VENTILATION HOLE POSITION OF ENCODER OUTPUT AND PROTECTION CAP ROTATABLE IN STEPS OF 90° X encoder cap: for SSI encoder: for Profibus encoder: for EtherCAT encoder: for CANopen encoder:

Open the catalog to page 4
SX300 Hydraulic transducer - 5

TECHNICAL DRAWING Flange type F2 (piston sealing) 196,5 SCREWED SEALING PLUG VENTILATION HOLE FLANGE SEALING: O-RING 123,42 x 3,53 (NBR) AND BACK-UP RING 146 POSITION OF ENCODER OUTPUT AND PROTECTION CAP ROTATABLE IN STEPS OF 90° X encoder cap: for SSI encoder: for Profibus encoder: for EtherCAT encoder: for CANopen encoder:

Open the catalog to page 5
SX300 Hydraulic transducer - 6

INSTALLATION The wire fixation unit has to be screwed into the piston of the cylinder and locked with counter nut. Note: use screw locking device. If it is not possible to work through the cylinder head bore, you have to take off the cylinder head (please refer to the cylinder manual). Drawing contains O-ring (blue) installed in cylinder head bore. This is not necessary! The SX300-...-F2 already features an O-ring sealing on its flange. Install 3 stud bolts at the cylinder head. It is necessary to use stud bolts on the underside of the sensor flange, as conventional screws (e.g. according...

Open the catalog to page 6
SX300 Hydraulic transducer - 7

Move the transducer toward the cylinder head and insert the stud bolts through the bores in the flange. Note: Avoid leading the rope over edges or corners. Be careful not to damage the O-ring. Do not operate the sensor if there are buckles or damages in the draw wire. Tearing the draw wire may cause injury or damage to the sensor. Mount the fixing screws through the flange and tighten them crosswise with a torque of 100 Nm in the first step. Note: The fastening screws must be greased with MoS2 during assembly, unless otherwise described. Please follow the operating instructions for the...

Open the catalog to page 7
SX300 Hydraulic transducer - 8

ACCESSORIES Piston wire fixation clip fixation rope clip hydraulic cylinder housing Messbereich [m] 10 / 15 Sensor without encoder Draw wire mechanics 1⁾ Sensor with encoder SSI CANopen Profibus DP EtherCAT Profinet Flange type rod sealing type (only on request) piston sealing type (standard) 1⁾ Encoder requirements: • flange with stator coupling Ø 58 mm • pitch circle diameter fixing screws Ø 63 mm • hollow shaft Ø 15 mm Subject to change without prior notice. WayCon Positionsmesstechnik GmbH email: info@waycon.de internet: www.waycon.biz

Open the catalog to page 8