- Measurement ranges 50 mm up to 50.8 m - Distance measurement and Tachometer - Intrinsically safe model (UL, CSA certified) - Linearity up to ±0.1 % - Output: Analog, TTL or speed - 2 designs, depending on the full scale - Easy installation - Stainless steel wire - Working temperature max. -20...+95 °C - Protection class IP68

Open the catalog to page 1
Draw wire sensor HX - 2

stainless steel and anodised aluminium stainless steel mounting base and corrosion-free thermoplastic housing Lifespan (full cycles)

Open the catalog to page 2
Draw wire sensor HX - 3

DESCRIPTION HX-EP Resolution Utilising an incremental encoder as the sensor, the HX-EP series provides a two-channel square wave current sinking output signal in quadrature. The standard output is a single-ended TTL compatible square. The resolution values shown in the specifications table indicate resolution for times 1 counting mode where a count is registered for one up transition in A channel. With interface electronics capable of times 2 or times 4 counting mode, a true resolutional increase of 2 or 4 may be obtained. The actual resolution of a HX-EP sensor differs from unit to unit...

Open the catalog to page 3
Draw wire sensor HX - 4

Dimension "C” is the cable offset that occurs as the cable is extended from the transducer. C = 0.0016 mm x E, where E = extension in mm. Note: Sensor mounts with M6 cylinder head screws . Note: Sensor mounts with M12 cylinder head screws.

Open the catalog to page 4
Draw wire sensor HX - 5

ELECTRICAL CONNECTION HX-PA Position Potentiometer Position Potentiometer load resistance / input voltage 1400 Position Potentiometer +Vout -Vout HX-VP Tachometer Positive output occurs with cable extending. supply voltage, V Vmin = 0.02 R + 9 VDC +Vin A GND B +Vout C D +Vout E -Vout F Position Potentiometer Tachometer Positive output occurs with cable extending. WARNING NOTICES • Don’t let the rope snap back. If the rope is retracted freely, this may lead to injuries (whiplash effect) and the device may be damaged. Caution when unhooking and retracting the rope into the sensor. • Never...

Open the catalog to page 5
Draw wire sensor HX - 6

OPTIONS Option Order code Nylon jacketed draw wire (measurement ranges ≤2 m) Replaces standard stainless steel wire rope with Ø 0.46 mm nylon jacketed wire rope. This option increases wire life dramatically but may increase non-linearity by as much as ±0.05% of full scale. Nylon jacketed draw wire (measurement ranges 2.5...12.7 m) Replaces standard stainless steel wire rope with Ø 0.94 mm nylon jacketed wire rope. This option increases wire life dramatically but may increase non-linearity by as much as ±0.05% of full scale. Inverted output signal Output is at maximum when wire rope is fully...

Open the catalog to page 6
Draw wire sensor HX - 7

ORDER CODE HX-PA HX-PA Draw wire tension Standard Reduced (MR ≤2 m) Rope outlet Standard top Left side Right side Bottom Potentiometer resistance Standard 1 kΩ 5 kΩ (MR ≥250 mm) 10 kΩ (MR ≥250 mm) Output signal Standard Inverted Connection type IP68 Cable output (0.3 m) Cable output (3 m) Cable output (4 m) Cable output (5 m) Cable output (6 m) Cable output (7 m) Connection type IP65 Connector output, 6-polig Connector type IP68 Cable with open ends Cable with connector at cable end Housing option Standard IP65 IP68 Corrosion protection + IP68 Draw wire Standard stainless steel Nylon...

Open the catalog to page 7
Draw wire sensor HX - 8

HX-P510 - Measurement range MR see„Mechanical Data" Connector type IP65 C Connector with mating connector K Con. without mating connector Connector type IP68 N Cable with open ends K Cable with connector at cable end Draw wire tension Standard Reduced (MR <2 m) Rope outlet Standard top Left side Right side Bottom

Open the catalog to page 8
Draw wire sensor HX - 9

Rope outlet Standard top Left side Right side Bottom Connection type IP68 Cable output (0.3 m) Cable output (3 m) Cable output (4 m) Cable output (5 m) Cable output (6 m) Cable output (7 m) Housing option Standard IP65 IP68 Corrosion protection + IP68 Connector type IP65 Connector with mating connector Con. without mating connector Connector type IP68 Cable with open ends Cable with connector at cable end Draw wire tension Standard Reduced (MR ≤2 m) Connection type IP65 Connector output, 6-polig Connector type IP68 Cable with open ends Cable with connector at cable end Draw wire Standard...

Open the catalog to page 9
Draw wire sensor HX - 10

ACCESSORIES Connection cable for HX with IP65 Connection cable for HX with IP68 and connector type K 10119-3M 3 m, with mating connector 10424-3M 3 m, with mating connector 10119-4M 4 m, with mating connector 10424-4M 4 m, with mating connector 10119-5M 5 m, with mating connector 10424-5M 5 m, with mating connector 10119-6M 6 m, with mating connector 10424-6M 6 m, with mating connector 10119-7M 7 m, with mating connector 10424-7M 7 m, with mating connector Subject to change without prior notice. WayCon Positionsmesstechnik GmbH email: info@waycon.de internet: www.waycon.biz