Draw Wire Sensors MH60
9Pages

{{requestButtons}}

Catalog excerpts

Draw Wire Sensors MH60 - 1

Series MH60 for mobile hydraulics applications Key-Features: - Cost-effective sensor for construction machinery - Measurement ranges from 1 to 4 m - extreme robust construction - Analog outputs: Potentiometer, 0...5 V, 0...10 V, 4...20 mA, optional redundant - teachable outputs: 0...5 V, 0...10 V, with an additional Open-Collector switching output - Digital output: CANopen, optional redundant - Linearity up to ±0.1 % of full scale - Protection class up to IP69K (suitable for close-range high pressure, high temperature spray downs) - Temperature range -20...+85 °C (optional -40 °C)

Open the catalog to page 1
Draw Wire Sensors MH60 - 2

INTRODUCTION The draw wire sensors of the mobile hydraulic series MH were specially developed for the demanding area of construction machines and construction equipment. The sensor can be individually configured depending on the application, in which it is used. Small adhesive and abrasive particles with small grain size can easily be removed when using the open MH versions. Seawater resistant protective grating provide a maximum protection against larger foreign objects like tree branches. In case of applications with high safety requirements, thicker stainlesssteel wire ropes are...

Open the catalog to page 2
Draw Wire Sensors MH60 - 3

TECHNICAL DATA Measurement range Draw wire diameter Improved linearity L25 Improved linearity L10 1) Sensor element Output signals potentiometer, 0...5 V, 0...10 V, 0...5 V (teachable), 0...10 V (teachable), 4...20 mA, CANopen Redundant output signals optional for: potentiometer, 0...5 V, 0...10 V, 4...20 mA, CANopen connector output M12 radial or cable output radial (TPE cable, standard length 2 m) Protection class IP67, optional IP69K (only in combination with cable output) see output types below Rope extraction speed Extraction force Aluminium, spring case PA6 up to approx. 500...

Open the catalog to page 3
Draw Wire Sensors MH60 - 4

DIGITAL OUTPUT CANopen CAN specification Communication profile Device profile Encoder, absolute linear; CIA 406 V 3.2.0 Error control Producer Heartbeat, Emergency Message, Node Guarding Default: 7, configurable via SDO and Squeezer (offline configuration) 1) 1 x TPDO, static mapping Event-triggered, Time-triggered, Sync-cyclic, Sync-acyclic Transmission rate 1 Mbps, 800, 500, 250, 125, 50, 20 kbps configurable via SDO and Squeezer (offline configuration) 1) Integrated Bus termination resistor 120 Ω, connectible via SDO and Squeezer (offline configuration) 1) Current consumption Measurement...

Open the catalog to page 4
Draw Wire Sensors MH60 - 5

OPTIONS The following table gives an overview of frequently used options, with which the standard sensors can be equipped. Option Improved linearity (not in combination with S1 or S2; further restriction see page 3) Inverted output signal (only analog output) Description Improved linearity 0.1 % (L10) or 0.25 % (L25) The analog signal of the sensor is increasing by extracting the rope (standard). Option IN inverts the signal, i.e. the signal of the sensor declines by extracting the rope. range retracted Redundant output signal Changed rope outlet (only in combination with C1 or C3) By using...

Open the catalog to page 5
Draw Wire Sensors MH60 - 6

Draw wire sensors with the analogue output versions 5VT and 10VT are equipped with teachable, internal electronics, called VT-Electronics. The signals provided by the sensor's potentiometer are digitized by the VT-Electronics. This digital information is first processed by the electronics, then transformed back and given out as an analogue output signal 0 to 5 V or 0 to 10 V. The digitization offers two possibilities of adjustment, by which the sensor can be configured individually using the Squeezer: 1. Teaching of the measurement range. After a successful teaching process, the squeezer...

Open the catalog to page 6
Draw Wire Sensors MH60 - 7

Single analog signal WARNING NOTICES • Do not let the rope snap back. If the rope is retracted freely, this may lead to injuries (whiplash effect) and the device may be damaged. • Caution when unhooking and retracting the rope into the sensor. • Never exceed the specified measurement range when extracting the rope! • Do not try to open the device. The stored energy of the spring drive may lead to injuries when being mishandled. • Do not touch the rope when operating the sensor. • Avoid guiding the rope over edges or corners. Use a deflection pulley instead. • Do not operate the sensor if...

Open the catalog to page 7
Draw Wire Sensors MH60 - 8

11 offline configurable via Squeezer 2) 5 pole in combination with WCAN or option R4 8 pole in combination with WCANP or options R1, R2, R3 3) Length in m (Minimum 2 m) Examples: KA02 = 2 m, KA05 = 5 m Description (see page 6) improved linearity ±0.1 % improved linearity ±0.25 % (possible combination for improved linearity see page 3) inverted output signal redundant output signal 1R redundant output signal 5V, 10V redundant output signal 420A redundant output signal WCAN rope outlet on the right side (only in combination with C1 or C3) rope outlet on the left side (only in combination with...

Open the catalog to page 8
Draw Wire Sensors MH60 - 9

SQUEEZER2M accessory for VT or WCANP output, 2 m cable MGG1 magnetic clamp SQUEEZER5M accessory for VT or WCANP output, 5 m cable SV1-XXXX rope extension (150 mm up to 4995 mm) SQUEEZER10M accessory for VT or WCANP output, 10 m cable SV2-XXXX rope extension (5000 mm up to 19995 mm) UR2 deflection pulley (for rope diameter 0.5 mm) SV3-XXXX rope extension (20000 mm up to 40000 mm) Cable with mating connector M12, 4 poles, shielded Cable with mating connector M12, 8 poles, shielded Mating connector M12, 4 poles, shielded D4-G-M12-S straight, M12 for self assembly D4-W-M12-S angular, M12 for...

Open the catalog to page 9

All WayCon Positionsmesstechnik GmbH catalogs and technical brochures