Temperature and Power Controllers catalog - Watlow - #89

/ 420


catalogue search
P. 51
P. 52
P. 53
P. 54
P. 55
P. 56
P. 57
P. 58
P. 59
P. 60
P. 61
P. 62
P. 63
P. 64
P. 65
P. 66
P. 67
P. 68
P. 69
P. 70
P. 71
P. 72
P. 73
P. 74
P. 75
P. 76
P. 77
P. 78
P. 79
P. 80
P. 81
P. 82
P. 83
P. 84
P. 85
P. 86
P. 87
P. 88
P. 89
P. 90
P. 91
P. 92
P. 93
P. 94
P. 95
P. 96
P. 97
P. 98
P. 99
P. 100


See other catalogues for Watlow

Text version of the page
Sensor and Controller Catalog table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:8.00pt "Arial", sans-serif; } .font3 { font:9.00pt "Arial", sans-serif; } .font4 { font:10.00pt "Arial", sans-serif; } .font5 { font:11.00pt "Arial", sans-serif; } .font6 { font:14.00pt "Arial", sans-serif; } .font7 { font:16.00pt "Arial Black", sans-serif; } .font8 { font:6.00pt "Georgia", serif; } .font9 { font:13.30pt "Georgia", serif; } .font10 { font:41.00pt "Verdana", sans-serif; } Thermocouples High Temperature Exotic Metal Sheath Metal Transitions L (Lead tolerance +4 / -0 in.) - E -► • High temperature insulations • Loose pack assemblies • Transition with lead wire termination • Standard maximum continuous operating temperature of 500°F (260°C) for the transition. 3 s Ordering Information Part Number Sheath O.D. © Lead Wire Const. ® Sheath Material m © Sheath Length "L" (fract. in.) © Junction @ Calibration Lead Wire 1 Length 1 HF ® Sheath O.D. G = 0.125 H = 0.188 J* = 0.250 * Not available with molybdenum sheath. Sheath Length "L" (in.) Whole inches: 01 to 60 0 = Sheath Length "L" (fractional in.) 0 4 = Lead Wire Construction A = Fiberglass solid - standard U = Junction Ungrounded - Single J= Fiberglass solid - overbraid © Lead Wire Termination A = Standard plug B = Standard jack C = Standard plug with mating connector F = Miniature plug G = Miniature jack H = Miniature plug with mating connector T = Standard - 1!2 in. split leads U = 1j2 in. split leads with space lugs W = 1in. split leads with BX connector and spade lugs Contact Factory Ungrounded - Dual i | Calibration B = ASTM Type B - Standard limits R = ASTM Type R - Standard limits S = ASTM Type S - Standard limits Note: For special limits contact the factory. Lead Wire Length "E" (ft) Whole feet: 01 to 25 (01 foot standard) Special Requirements Insulation B = Loose pack AI2O3 M = Standard 500°F (260°C) potting D = Loose pack HfO2 Sheath Material 3 = | Molybdenum Q = Alloy 600 WATLOW® 87

pageCatalog pdf di En 2012-06-22-01