W A T L O W
Open loop break protection >
PID with Time/Temperature
Profiling Controllers
Indication of thermal loop problem NEMA 4X (IP65) >
SERIES 96_AA
Watlows SERIES 96 is a powerful >
1 ⁄ >
16 DIN dual display controller thatoffers many advanced functions.
This new controller can be tailored toperform hardware and softwareneeds with hardware modules that
are plugable and exchangeable,
and software menus that may be
user programmed to fit exactapplication requirements.With one universal input, a secondauxiliary input and four outputs the
SERIES 96 can be programmed toperform:
temperature measurement,
input event switching, heating, boost
heating, cooling, alarms, digitalcommunications and retransmit.With fast 10Hz
industrial sampling, variabletime base burst firing outputs, NEMA4X front panel and 0.1 percent
calibration accuracy, this controller
can easily handle some of the
toughest application needs. Performance Capabilities Operating environment 0 to 65C (32 to 149F) Features and Benefits Profiles >
PID with Time/Temperature Profiling Two (2) 8-step profiles can belinked to create one (1) 15-step
profile Increase heater life / bettertemperature controlability Burst fire One input, one auxiliary input, fouroutputs >
Single-Loop Powerful flexibility at a competitiveprice Improved control responsiveness Fast 10Hz sampling >
Input 1Process
Input 2Event
Output 1ControlOutput 2Control or AlarmOutput 3AlarmOutput 4Alarm, Analog or Communications 96 No dipswitches Field expandable >
1 234% Easily configurable from the frontpanel Plugable output modules Flexible automatic control Multiple set points Specifications Controller >
1 Microprocessor-based, userselectable control modesHeat and cool auto-tune for control outputsUniversal input one, auxiliaryinput two, four outputsControl outputs user selectable ason-off, P, PI, PID Water and corrosion resistant frontpanel can be washed down Compact size Allows it to be mounted in smallareas Automatic tuning Easy one step tuning of PIDcontrol parameters Three-year warranty >
2 Provides Control Confidence >
Applications PackagingSemiconductor
Food processing
Lab equipment
Industrial furnace and ovens
Plastics >
1 To effect NEMA4X(IP65) rating requires aminimum mounting panel thickness of 1.5 mm(0.06 in.) and surface finish not rougher than0.000812 mm (0.000032 in.). 2 Electromechanical relays warranted for 100,000
closures only.Solid state switching devicesrecommended for applications requiring fast cycletimes or extended service life. 69 >