W A T L O W

Control/Alarm Outputs (1 - 4) Î (dc)maximum @ 0.5A•Switched dc 22 to 28V •User selectable as: on-off, P, PI,PD, PID, heat, cool, alarm action or retransmit with process output type hardware•Open collector/switched dc •Open collector 42V Î (dc)limited @ 30mA•Solid state relay manufacturer, Form A, 0.5A @24V

Auto-Tuning Pid controllers

Universal Inputs (Electrically Isolated) Å (ac) minimum, 264V Å (ac)maximum, opto-isolated, without contact suppression•User-selectable 0-10V

SERIES PDSingle Loop

Thermocouple, grounded orungrounded sensors•INDUSTRIAL RTD 2-or 3-wire, platinum, 100 Î (dc), 1K Ω minimum, scalable, 0-20mA @800 Ω maximum, scalable Ω @ 0°C calibration to DIN-curve (0.00385 Specifications Ω / Ω /°C)•Process 0-20mA @ <100 Power Ω ,or 0-10V •24V ı (ac/dc), +10/-15 percent,50/60Hz, ±5 percent•12VA maximum powerconsumption•Data retention upon power failurevia nonvolatile memory Î (dc) @ 10k Ω inputimpedance (50,000 bits @ fullscale) Digital Inputs Ω input impedance •Contact or dc voltage •10K Current Transformer Inputs •0 to 50mA CT input into 100 Ω impedance •0 to 65°C (32 to 149°F) operatingtemperature•-40 to 85°C (-40 to 185°F) storagetemperature•0 to 90 percent RH, non-condensing Allowable Input Operating Range Environment •Calibration accuracy and sensorconformity: ±0.1 percent of span,±1°C @ the calibrated ambient temperature and rated line voltage •Calibration ambient temperature= 25°C ±3°C (77°F ±5°F) •Accuracy span: 540°C (1000°F)minimum•Temperature stability: ±0.1°C/°C(±0.2°F/°F) rise in ambientmaximum Type J:-200to1200°C(-328to2192°F)Type K:-270to1370°C(-454to2500°F)Type T:-270to400°C(-454to750°F)Type N:-270to1300°C(-454to2372°F)Type E:-270to975°C(-454to1790°F)Type C:0to2315°C(32to4200°F)Type D:0to2315°C(32to4200°F)Type PTII:0to1395°C(32to2543°F)Type R:0to1760°C(32to3200°F)Type S:0to1760°C(32to3200°F)Type B:0to1815°C(32to3300°F)RTD (DIN):-200to800°C(-328to1470°F)Process V:0to10V
Single-Loop Auto-Tuning PID Accuracy •Electromechanical relay. Form C,rated 5A @ 120V Å (ac) or 5A @240V •TCP/IP/Ethernet •Modbus™ TCP•Ethernet RJ 45 connector, 10 base T•HTTP interface•DHCP, auto IP or fixed IP address Å (ac) or 5A @ 30V Î (dc) Communications Agency Approvals •UL Dimensions •Width x height x depth42 mm x 116 mm x 132 mm (1.64 in. x 4.56 in. x 5.19 in.) DIN-rail or chassis mount, DIN-rail spec DIN 5022 35 mm x 7.5 mm (1.38 in. x 0.30 in.)
® 508, C-UL
® , CSA and CE Controller •Microprocessor based user-selectable control modes•Single or dual channel universalinputs•Current transformer inputs/digitalinputs•Up to four programmable outputs•Update rates, inputs = 10Hz,outputs = 10Hz Î (dc)Process I:0to20mA Operator interface •Browser based INDUSTRIAL HMI (HumanMachine Interface) Wiring Termination •Touch industrial safe removable terminals •14 to 22 AWG 51
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 51 p.51
page 52 p.52
page 53 p.53
page 54 p.54
page 55 p.55
page 56 p.56
page 57 p.57
page 58 p.58
page 59 p.59
page 60 p.60
page 61 p.61
page 62 p.62
page 63 p.63
page 64 p.64
page 65 p.65
page 66 p.66
page 67 p.67
page 68 p.68
page 69 p.69
page 70 p.70
page 71 p.71
page 72 p.72
page 73 p.73
page 74 p.74
page 75 p.75
page 76 p.76
page 77 p.77
page 78 p.78
page 79 p.79
page 80 p.80
page 81 p.81
page 82 p.82
page 83 p.83
page 84 p.84
page 85 p.85
page 86 p.86
page 87 p.87
page 88 p.88
page 89 p.89
page 90 p.90
page 91 p.91
page 92 p.92
page 93 p.93
page 94 p.94
page 95 p.95
page 96 p.96
page 97 p.97
page 98 p.98
page 99 p.99
page 100 p.100
Pages:
1-50
51-100
101-150
151-200
201-232