A T L O
Auto-Tuning PID Controllers
Type E:
-200
to
800°C
(-328
to
1470°F)
Type C:
0
to
2315°C
(32
to
4200°F)
Type D:
0
to
2400°C
(32
to
4352°F)
Type Pt 2:
0
to
1395°C
(32
to
2543°F)
Type R:
0
to
1760°C
(32
to
3200°F)
Type S:
0
to
1760°C
(32
to
3200°F)
Type B:
0
to
1816°C
(32
to
3300°F)
RTD (DIN):
-200
to
800°C
(-328
to
1472°F)
RTD (JIS):
-200
to
800°C
(-328
to
1166°F)
Process: -19,999
to
30,000 units
Sensor Accuracy
Ranges
Input ranges
Type J:
0
to
815°C
(32
to
1500°F)
Type K:
-200
to
1370°C
(-328
to
2500°F)
Type T:
-200
to
400°C
(-328
to
750°F)
Type N:
0
to
1300°C
(32
to
2372°F)
Type E:
-200
to
800°C
(-328
to
1470°F)
Type C:
0
to
2315°C
(32
to
4200°F)
Type D:
0
to
2400°C
(32
to
4352°F)
Type Pt 2:
0
to
1395°C
(32
to
2543°F)
Type R:
0
to
1760°C
(32
to
3200°F)
Type S:
0
to
1760°C
(32
to
3200°F)
Type B:
0
to
1816°C
(32
to
3300°F)
RTD (DIN):
-200
to
800°C
(-328
to
1472°F)
RTD (JIS):
-200
to
800°C
(-328
to
1166°F)
Process: -19,999
to
30,000 units
• 39VA maximum power consumption
• Data retention upon power failure via nonvolatile memory. Sensor input isolation from input to input to output to communication circuitry is 500V~(ac),
Operating Environment
• 0 to 65°C (32 to 149°F)
• 0 to 90 percent RH, non-condensing
• Storage temperature: -40 to 70°C (-40 to 158°F)
• Calibration accuracy and sensor conformity: ±0.1 percent of span ±1°C @ 25°C ±3°C (77°F ±5°F) ambient, and rated line voltage ±10 percent with the following exceptions:
Type T: 0.12 percent of span for
-200°C to -50°C (-328°F to -58°F)
Types R and S: 0.15 percent of
span for 0°C to 100°C (32°F to 212°F)
Type B: 0.24 percent of span for
870°C to 1700°C (1598°F to 3092°F)
• Accuracy span: Less than or equal to operating ranges, 540°C (1000°F) minimum
• Temperature stability: ±0.1°C/°C (±0.1°F/°F) rise in ambient for thermocouples
• ±0.05°C/°C (±0.05°F/°F) rise in
ambient for RTD sensors Displays
• Process: 5, seven-segment LED red
• Control interface display: high-definition LCD green
Sensor Operating Ranges
SERIES F4P
Specifications Cont. Electromechanical Relay
• Form C, 2A @ 250V~(ac) or 30V^(dc) max.
• Resistive or inductive load
• Without contact suppression
Process Outputs (Optional Retransmit)
• Update rate = 1Hz
• User-selectable 0-10V=(dc), 0-5V^(dc), 1-5V^(dc) @1KQ min., 0-20mA, 4-20mA @ 8000 max.
• Resolution:
dc ranges = 2.5mV nominal mA ranges = 5uA nominal
• Calibration accuracy:
dc ranges = ±15mV mA ranges = ±30uA
• Temperature stability 100ppm/°C Alarm Outputs
• Output update rate 1Hz
• Electromechanical relay, Form C, 2A @ 30V^(dc) or 240V~(ac) max.
Communications
• EIA-232 and EIA-485 serial communications with Modbus™ RTU protocol. 9600 or 19.2K baud rate
Safety and Agency Approvals
•UL®/C-UL®916-listed,
File # E185611 process control equipment
• NEMA 4X and IP65
• CE to EN 61010-1 and 61326 Terminals
• Touch-safe, removable terminal blocks, accepts 12 to 22-gauge wire
Power
• 100-240V~(ac), -15 percent,
+ 10 percent; 50/60Hz, ±5 percent
• 24-28Vi(ac/dc), -15 percent, +10 percent (order option)
a CO
0 =
1 -
Type J:
0
to
815°C
(32
to
1500°F)
Type K:
-200
to
1370°C
(-328
to
2500°F)
Type T:
-200
to
400°C
(-328
to
750°F)
Type N:
0
to
1300°C
(32
to
2372°F)
47