QuickReference Guide

ControllerControlLoop Inputs Outputs PowerSupply

Single-Loop

Auto-Tuning

11 universal -2 outputs100-240V (ac)Hardware: Thermocouple, RTD, V (dc), mAFunction: Control - Heat/Cool, Alarm24V ı (ac/dc)Hardware: Switched dc, Open Collector,SSR, EMR, V (dc), mA SERIES SD31 Page 27 Watlow USA Manufacturing Facility (F.O.B.): Winona, Minnesota 11 universal -3 outputs, 2 outputs on
1 ⁄
32 DIN100-240V (ac)Hardware: Thermocouple, RTD, V (dc), mAFunction: Control - Heat/Cool, Alarm24V (dc), mA ı (ac/dc)Hardware: Switched dc, Open Collector, SSR, EMR, V SERIES SD_C Page 29 Watlow USA Manufacturing Facility (F.O.B.): Winona, Minnesota 11 universal -2 outputs100-240V (ac)Hardware: Thermocouple, RTD, V (dc), mAFunction: Control - Heat/Cool, Alarm24V ı (ac/dc)Hardware: Switched dc, SSR, EMR, V (dc), mA SERIES SD6C_D Page 33 Watlow USA Manufacturing Facility (F.O.B.): Winona, Minnesota 11 universal -4 outputs100-240V (ac)Hardware: Thermocouple, RTD, V (dc), mAFunction: Control - Heat/Cool, Alarm, 24V ı (ac/dc)1 auxiliary -Retransmit Functions: Event, Remote Set point inputHardware: Switched dc,Open Collector, Hardware: V (dc, Resistance contact)SSR, EMR, V (dc), mA SERIES 96 Page 35 Watlow USA Manufacturing Facility (F.O.B.): Winona, Minnesota 11 universal -4 outputs100-240V (ac)Hardware: Thermocouple, RTD, V (dc), mAFunction: Control - Heat/Cool, Alarm, 24V ı (ac/dc)2 auxiliary - Retransmit, Duplex, Signal conditioner Functions: Event, Remote Set point, Slidewire, power supplyPotentiometer, Current transformer, Cascade, Hardware: Switched dc, Open Collector, Differential, Ratio SSR, EMR, V (dc), mAHardware: Thermocouple, RTD, V (dc), mA,Resistance contact SERIES 988/989 Page 39 Watlow USA Manufacturing Facility (F.O.B.): Winona, Minnesota
Abbreviation Legend SW (dc) = Switched Direct CurrentDC Pw. Sup. = DC Power SupplyEMR = Electromechanical RelayH = HorizontalH/V = Horizontal or VerticalHum./Dehum.= Humidify/DehumidifyInt./Ext. = Internal/ExternalLCD = Liquid Crystal DisplayLED = Light Emitting DiodemA = MilliampN/A = Not ApplicableOC = Open CollectorOpt. Rmt. = Optional RemoteRetx = RetransmitRev/Dir = Reverse/DirectUL