Catalogue Temperature and Power Controllers catalog
www.watlow.com
print switch display
Page / 232
Watlow - 2949, 2526, 68620, 2254, 16679, 14774
/ 232
See other catalogues for Watlow
Text version of the page
Specifications Cont. Operator interface

Auto-Tuning PIDControllers

Allowable Operating Range •Dual 4 digit, 7 segment LEDdisplays•Advance, infinity and up downkeys•Optional IrDA infrared port (notavailable on Type J:0to815°C(32to1500°F)Type K:-200to1370°C(-328to2500°F)Type T:-200to400°C(-328to750°F)Type N:0to1300°C(32to2372°F)Type E:-200to800°C(-328to1470°F)Type C:0to2315°C(32to4200°F)Type D:0to2315°C(32to4200°F)Type PTII:0to1395°C(32to2543°F)Type R:0to1760°C(32to3200°F)Type S:0to1760°C(32to3200°F)Type B:0to1816°C(32to3300°F)INDUSTRIAL RTD (DIN):-200to800°C(-328to1472°F)Process:-1999to 9999 units

SD_C

Accuracy •Calibration accuracy and sensor conformity: ±0.1 percent of span, ±1°C @ the calibrated ambient temperature and rated line voltage•Calibration ambient temperature = 25°C ±3°C (77°F ±5°F) •Accuracy span: 540°C (1000°F)minimum•Temperature stability: ±0.1°C/°C(±0.2°F/°F) rise in ambient maximum
1 â„
32 DIN)•Isolated EIA-485 Modbus™ serialcommunications. 9600,19.2K or 38.4K baud rates Agency Approvals Wiring Termination -Touch SafeTerminals •UL •Input power and control outputs12 to 22 AWG•Sensor inputs and processoutputs 20 to 28 AWG Universal Input •Thermocouple, grounded orungrounded sensors•RTD 2- or 3-wire, platinum, 100
® 3121, C-UL
® ‚ CSA, CE,NEMA 4X/IP65•Limit version features FM approval •NSF for Type J, K, T and Ethermocouples Ω / Ω /°C)•Process, 0-20mA @ 100 Ω @ 0°C calibration to DIN- curve (0.00385 Ω , or 0-10V Control OutputsOutputs 1, 2 , 3 (Output 3 notavailable on Controller Î (dc) @ 20k Ω inputimpedance; Scalable•Inverse scaling•>20M •Microprocessor based user-selectable control modes•Single universal input, up to threeoutputs•Control industrial sampling rates: Input = 6.5Hz, Display = 10Hz, and Outputs = 6.5Hz Ω input impedance•Maximum of 20 Ω sourceresistance
1 â„
32 DIN) •User selectable for heat/cool ason-off, P, PI, PD, PID or Alarm action. Not valid for limit controls•Electromechanical relay. Form A,rated 2A @ 120V Å (ac), 2A @240V Dimensions Å (ac) or 2A @ 30V Î (dc)•Switched dc non-isolatedminimum turn on voltage of 6V Î (dc) into a minimum 500 Ω
DIN SizeBehind PanelWidthHeight(max.) load with a maximum on voltageof not greater than 12V
1 â„ 32 DIN97.8 mm52.6 mm29.7 mm(3.85 in.)(2.07 in.)(1.17 in.) Î (dc) intoan infinite load. Maximum switched industrial dc power supply current available for up to two outputs is 60mA•Solid state relay, Form A, 0.5A @24V Å (ac) minimum, 264V Å (ac)maximum, opto-isolated, withoutcontact suppression
1 â„ 16 DIN97.8 mm52.1 mm52.1 mm(3.85 in.)(2.05 in.)(2.05 in.) 1 â„ 8 DIN97.8 mm52.8 mm99.8 mmVertical(3.85 in.)(2.08 in.)(3.93 in.) 1 â„ 8 DIN97.8 mm99.8 mm52.8 mmHorizontal(3.85 in.)(3.93 in.)(2.08 in.) 1 â„ 4 DIN101.1 mm99.8 mm99.8 mm(3.98 in.)(3.93 in.)(3.93 in.) 30
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-150
151-200
201-232