A T L O
Auto-Tuning PID Controllers
F.O.B.: Winona, Minnesota
SERIES 998/999
Specifications Cont.
• Open collector or switched dc signal provides a minimum turn on voltage of 3V^(dc) into a minimum 500Q load; maximum on voltage not greater than 32V^(dc) into an infinite load, isolated
• Electromechanical relay®, Form C, 5A @ 120/240V~(ac), 6A @ 28V^(dc), 1/8hp. @ 120V~(ac), 125VA @ 120V~(ac). With or without contact suppres­sion. Off state output impedance with RC suppression is 20kQ
• Retransmit: 0-20mA, 4-20mA with 600Q max. load impedance, or 0-5V=(dc), 1-5Vī(dc) and 0-10V^(dc) with 500Q min. load impedance
• EIA/TIA-232 or EIA/TIA-485, EIA/TIA-422 communications, opto-isolated
• External transmitter power supply, 5, 12 or 20V^(dc) @ 30mA
Line Voltage/Power
• 100-240Vi(ac/dc) +10 percent, -15 percent; 50/60Hz, ±5 percent
• 24-28Vi(ac/dc) +10 percent, -15 percent; 50/60Hz, ±5 percent
• Fused internally (factory replaceable only) Slo-Blo® type (time-lag)
2A, 250V for high voltage versions 5A, 250V for low voltage versions
• Power consumption 16VA maximum
• Data retention upon power failure via non-volatile memory
Availability
Four working days on orders less than 20 units. For orders over 20 units, consult factory for releases and shipment schedules.
® Electromechanical relays warranted for 100,000 closures only. Solid state switching devices recommended for applications requiring fast
cycle times or extended service life. b Not an ANSI symbol.
Slo-Blo® is a registered trademark of Littelfuse, Inc.
Ordering Information
To order, complete the code number to the right with the information below:
99D- -
TJ
SERIES 998/999 = Dual channel microprocessor based, dual input, six output temperature control, J8 DIN vertical or horizontal Hardware-
6 = 24-28Vi(ac/dc) nominal, vertical mounting
7 = 24-28Vi(ac/dc) nominal, horizontal mounting
8 = 100-240Vi(ac/dc) nominal, vertical mounting
9 = 100-240Vi(ac/dc) nominal, horizontal mounting Software-
D = Dual channel software S = Special customer feature
Channel A Input -
1 = Basic thermocouple signal conditioner (excluding Types B, R and S)
2 = Universal signal conditioner (see Range Information) Channel B Input -
1 = Basic thermocouple signal conditioner (excluding Types B, R and S)
2 = Universal signal conditioner (see Range Information) Channel A Outputs-
C = Dual switched dc, isolated
E = Dual electromechanical relay®, Form A, 2A, without contact suppression F = Single universal process. 0-5V==(dc), 1-5V==(dc), 0-10V==(dc).
0-20mA, 4-20mA, isolated K = Dual solid state relay, Form A, 0.5A, without contact suppression
Channel B Outputs-
C = Dual switched dc, isolated
E = Dual electromechanical relay®, Form A, 2A, without contact suppression F = Single universal process, 0-5V==(dc), 1-5V==(dc), 0-10V==(dc).
0-20mA, 4-20mA, isolated K = Dual solid state relay, Form A, 0.5A, without contact suppression
Output 3 -
A = None
B = Solid state relay, Form A, 0.5A, with RC suppression C = Switched dc or open collector, isolated
J = Electromechanical relay®, Form A or B, 5A, without contact suppression
K = Solid state relay, Form A, 0.5A, without contact suppression
M = Retransmit, 0-20mA, 4-20mA
N = Retransmit, 0-5V=(dc), 1-5V=(dc), 0-10=(dc)
T = External signal conditioner power supply, 5, 12 or 20V^(dc) @ 30mA
Output 4 -
None
Solid state relay, Form A, 0.5A, with RC suppression Switched dc or open collector, isolated Electromechanical relay®, Form C, 5A, with RC suppression Electromechanical relay®, Form C, 5A, without contact suppression Solid state relay, Form A, 0.5A, without contact suppression Isolated EIA/TIA-232 communications Isolated EIA/TIA-485/EIA/TIA-422 communications EIA/TIA-232, EIA/TIA-485 software selectable
External signal conditioner power supply, 5, 12 or 20VĪ(dc) @ 30mA Display/Overlay-
GG= Green/Green display RG = Red/Green display
GR = Green/Red display RR = Red/Red display
XX = Custom overlays or default settings
101