|
catalogue search
|
You may also be interested in
Resistance heater, RTD, Temperature controller, Power regulator, Heater
Text version of the page
W A T L O W ThermocouplesGeneral ApplicationsCustom Ordering Information Items in Bolded Green Type are preferredwith shorter lead times.PFA Encapsulated Style1234567891011651-2. Construction Style 65=PFA coated sheath 3. Diameter (inch) under covering C=1 ⁄ 8 epoxy seal 149C (300F) D= 3 ⁄ 16 epoxy seal 149C (300F) E= 1 ⁄ 4 epoxy seal 149C (300F) 4. CalibrationJ =Type J T =Type TK=Type KE =Type E LeadLength 5. Lead protection T = PFA (24 gauge stranded) *R = PFA (20 gauge stranded)6. JunctionU=Ungrounded, round tipG =Grounded, round tip7. Sheath Length (inches) B=1J=4 1 ⁄ 2 R=8C=1 1 ⁄ 2 K=5S=8 1 ⁄ 2 D=2L=5 1 ⁄ 2 T=9E=2 1 SheathLength ⁄ 2 M=6 U=9 1 ⁄ 2 F=3 N=6 1 ⁄ 2 W=10G=3 1 ⁄ 2 P=7Y=11 Thermocouples H=4 Q=7 1 ⁄ 2 Z=12 8-10. Lead Length (inches) 012, 024, 036, 040, 048, 060, 072, 079, 096 and 120 Available lengths: 006 to 360, over 360 consult factory 11. Terminations/OptionsA=Standard, 2 1 ⁄ 2 inch split leads B=2 1 ⁄ 2 inch split leads with #6 spade lugsC=2 1 ⁄ 2 inch split leads with #6 spade lugs and BX connector The rigid sheath is covered with a 0.010 inch (25 mm) wall of PFA for corrosion resistance in acid environ- ments. An epoxy seal improvesmoisture resistance of sensor andprovides a barrier for migrating fumes in corrosive applications.D=Standard male plug, quick disconnect E=Standard female jack, quick disconnectF=Miniature male plug, quick disconnectG=Miniature female jack, quick disconnectH=1 ⁄ 4 inch push-on connector *Not available in 1 ⁄ 8 inch diameter. 49 |