Sensor catalog - Watlow - #401

/ 420


catalogue search
P. 401
P. 402
P. 403
P. 404
P. 405
P. 406
P. 407
P. 408
P. 409
P. 410
P. 411
P. 412
P. 413
P. 414
P. 415
P. 416
P. 417
P. 418
P. 419
P. 420


See other catalogues for Watlow

Text version of the page
Sensor and Controller Catalog table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:7.00pt "Arial", sans-serif; } .font1 { font:9.00pt "Arial", sans-serif; } .font2 { font:10.00pt "Arial", sans-serif; } .font3 { font:11.00pt "Arial", sans-serif; } .font4 { font:18.00pt "Arial", sans-serif; } .font5 { font:13.00pt "Arial Black", sans-serif; } Control Panels Standard Control Panels Ordering Information Part Number Catalog part numbers include the following features: • Type 4 enclosure (carbon steel with gray paint) • Control transformer • Fused disconnect switch • Control and load fusing (feed and branch circuit) • Three position lighted selector switch (on, off, control power only) • Pilot light (EZPL models only) • High limit • Through-wall bus communications input (standard bus with 485) • Load power, remote interlock and sensor terminal blocks ® Opt. Process & Hi-Limit Sensor Part Number Control Panel CP = DIN-A-MITE® C power controller Process and/or Hi-Limit Control EZPR = EZ-ZONE® PM process controller only EZPL = EZ-ZONE PM Process and hi-limit controller Optional Process and Hi-Limit Sensors J = | Type J Input K = Type K Input Part Number See chart below for Part number Part Number Chart (Choose part number for Ordering Information 8, 9, 10 and 11 above.) Nominal Volts Phase A x B x C ** Enclosure Size in. Est. Shipping Weight (lbs) Part Number 208 8.6 3 1 24 16 x 16 x 8 110 2312 208 17.3 3 2 24 36 x 24 x 8 220 2322 208 25.9 3 3 24 36 x 30 x 8 290 2332 240 10.0 3 1 24 16 x 16 x 8 110 3312 240 19.9 3 2 24 36 x 24 x 8 220 3322 240 29.9 3 3 24 36 x 30 x 8 290 3332 480 19.9 3 1 24 16 x 16 x 8 110 4312 480 39.9 3 2 24 36 x 24 x 8 220 4322 480 59.8 3 3 24 36 x 30 x 8 290 4332 208 17.3 3 1 48 24 x 20 x 8 160 2314 208 34.5 3 2 48 36 x 36 x 8 330 2324 208 51.8 3 3 48 42 x 36 x 12 400 2334 240 19.9 3 1 48 24 x 20 x 8 160 3314 240 39.9 3 2 48 36 x 36 x 8 330 3324 240 59.8 3 3 48 42 x 36 x 12 400 3334 480 39.9 3 1 48 24 x 20 x 8 160 4314 480 79.7 3 2 48 36 x 36 x 8 330 4324 480 119.6 3 3 48 42 x 36 x 12 400 4334 120 2.9 1 24 16 x 16 x 8 110 1112 240 5.8 1 24 16 x 16 x 8 110 3112 240 11.5 2 24 36 x 24 x 8 220 3122 240 17.3 3 24 36 x 30 x 8 290 3132 120 5.8 1 1 48 24 x 20 x 8 160 1114 240 11.5 1 1 48 24 x 20 x 8 160 3114 240 23.0 2 48 36 x 24 x 8 230 3124 240 34.6 3 48 42 x 36 x 12 400 3134 * 24 amp circuits fused at 30 amps 48 amp circuits fused at 60 amps Installation must comply to local electrical codes ** Add 2/46 inch to "C" dimension for external heat sink. WATLOW® 397

pageCatalog pdf di En 2012-06-22-01