catalogue search
|
You may also be interested in
Sensor, RTD, Radiant heater, Resistance heater, Cartridge heater
Text version of the page
W A T L O WSensor catalog - 7347 GeneralInformationBendsG C Bend Radius For 10 to 90 Degree Bendseneral Information Watlow custom bends sensors for aprecise fit in many applications. The charts to the right list Watlows standard radius by sensor type with minimum length requirements. Customers also form many sensoritems at their own facility. Mineralinsulated sensors should not be benton a radius smaller than twice thesheath outside diameter. General application thermocouples andstandard industrial RTDs should not be bent with radius smaller thanindicated in the charts to the right.Support should also be given tothese items as not to collapse the protecting sheath and damage internal sensor wiring and insulation. For all sensor types the minimum H dimension should be maintained.10 - 90 Radius HGeneral Application Thermocouples Mineral Insulated ThermocouplesStandardMinimumMinimumDiameterBend RadiusH DimensionC Dimensionin.in.in.in. 0.1253 ⁄ 8 120.188 3 ⁄ 8 120.250 1 ⁄ 2 220.375 3 ⁄ 4 32 StandardMinimumMinimumDiameterBend RadiusH DimensionC Dimensionin.in.in.in. 0.063 3 ⁄ 161 ⁄ 2 1 1 ⁄ 2 0.090 1 ⁄ 43 ⁄ 4 1 1 ⁄ 2 0.125 3 ⁄ 8 1*20.188 1 ⁄ 2 1*20.250 3 ⁄ 4 220.3131 1 ⁄ 4 220.3751 1 ⁄ 2 320.500242 *For RTDs a minimum of 2 inches. RTDs and ThermistorsStandardMinimumMinimumDiameterBend RadiusH DimensionC Dimensionin.in.in.in. 0.1253 ⁄ 8 120.188 3 ⁄ 8 120.250 1 ⁄ 2 22 37 |