catalogue search
|
You may also be interested in
Band heater, Radiant heater, Resistance heater, Temperature limiter, Cartridge heater
Text version of the page
We offer:Calibration testing •For thermocouples, thermistorsand RTDs traceable to NIST standards End-to-end calibration •For thermocouple conductors Insulation resistance testing
Dielectric testing •Measures an insulation’s performance in the presence of electrical discharges Helium leak testing •Verifies sheath integrity Radiographic (X-ray) inspection •Detects internal defects, dimen-sional compliance and inclusions Liquid penetrant testing •Detects surface defects Metallographic examination •Evaluates constituents and structures of alloys
Sensor catalog - 7347 GeneralInformationCompaction density testing •Determines compaction of mineralinsulation in metal sheathedcablesLab ServicesToday’s demand for world classproducts that perform better, last longer, are more accurate and with-stand harsher environments has ledto an increased demand for certifiedcompliance with manufacturing stan- dards. Many high-tech industriesdemand certificates of complianceand traceability in the manufacturing process of the components they buy from you, their vendors. Watlow is able to meet this demand with ourcomplete testing and certificationservices.Watlow provides certification to verifythe finished sensor is built to allowinitial calibration tolerances as established by ASTM Standard E 230. This standard is based on the thermodynamic temperature scale of ITS 90, succeeding IPTS 68.These are initial tolerances as sup-plied by Watlow. All sensors are susceptible to change during use due to environmental factors such ascontamination, temperature, furnace gradient and physical abuse.Watlow has the advanced capabili-ties to calibrate your sensors over a broad range of temperatures, from cryogenic -195°C (-320°F) to1700°C (3090°F).ISO 10012 is used as the guide for all sensor and instrument calibrationmaking all results traceable to theNational Institute of Standards and Technology—NIST. Standard meth-ods and specifications for sensorcalibration used are:•ASTM E 207 •ASTM E 220•ASTM E 230•ASTM E 644 •AMS 2750C We will test and certify any tempera-ture sensing product—whether madeby Watlow, or not. Our objective is to provide you with a comprehensiveservice for determining compliancewith established standards.We will perform the tests and calibrations required and provide all necessary documentation for anadditional cost.Quality Certification LabThermal cycling •Assures ruggedness under thermal transients Micro-hardness• Vicker’s scale destructive testused to determine sheath hardness.All tested sensors and wire are tagged withdeviations and accompanied by a calibration report. 32 |