|
catalogue search
|
You may also be interested in
Resistive temperature detector, Strip heater, Cartridge heater, RTD, Cable
Text version of the page
Sensor and Controller Catalog table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:9.00pt "Arial", sans-serif; } .font3 { font:10.00pt "Arial", sans-serif; } .font4 { font:11.00pt "Arial", sans-serif; } .font5 { font:14.00pt "Arial", sans-serif; } .font6 { font:18.00pt "Arial", sans-serif; } .font7 { font:48.85pt "Arial", sans-serif; } .font8 { font:14.00pt "Georgia", serif; } Integrated Multi-Function EZ-ZONE PM Integrated PID Controller Model Ordering Information Universal Sensor Input, Standard Bus Communications, TRU-TUNE+ Adaptive Tune, Red and Green Seven-Segment Displays Part Number ® Package Size ® Primary Function © Power Supply, Digital I/O ® ® Output 1 and 2 Hardware Options ® Comm. Options or Add'l Digital I/O m © © Output 3 and 4 Hardware Options © Additional Options © ® Custom Options PM (3 Package Size 6 = î/6 DIN 8 = Î8 DIN vertical 9 = Î8 DIN horizontal 4 = Î4 DIN Primary Function Options B and E are not available with Me DIN (PM6) models C = PID controller with universal input R = PID controller with universal input and profiling ramp/soak B = PID controller with universal input and profiling ramp/soak and battery back-up with real time clock J = PID controller with thermistor input N = PID controller with thermistor input and profiling ramp/soak E = PID controller with thermistor input and profiling ramp/soak and battery back-up with real time clock S = Custom firmware © Power Supply, Digital Inputs/Outputs (I/O) 1 = 100 to 240VAC 2 = 100 to 240VAC plus 2 digital I/O points 3 = 20 to 28VAC or 12 to 40VDC 4 = 20 to 28VAC or 12 to 40VDC, plus 2 digital I/O points ©M Output 1 and 2 Hardware Options Output 1 Output 2 CA = Switched dc/open collector None CH = Switched dc/open collector NO-ARC 15A power control CC = Switched dc/open collector Switched dc CJ = Switched dc/open collector Mechanical relay 5A, Form A CK = Switched dc/open collector SSR Form A, 0.5A EA = Mechanical relay 5A, Form C None EH = Mechanical relay 5A, Form C NO-ARC 15A power control EC = Mechanical relay 5A, Form C Switched dc EJ = Mechanical relay 5A, Form C Mechanical relay 5A, Form A EK = Mechanical relay 5A, Form C SSR Form A, 0.5A FA = Universal process None FC = Universal process Switched dc FJ = Universal process Mechanical relay 5A, Form A FK = Universal process SSR Form A, 0.5A AK = None SSR Form A, 0.5A KH = SSR Form A, 0.5A NO-ARC 15A power control KK = SSR Form A, 0.5A SSR Form A, 0.5A g Communication Options or Additional Digital Inputs/Outputs (I/O) Standard bus always included A = None 1 = EIA 485 Modbus® RTU 2 = EIA 232/485 Modbus® RTU 3 = EtherNet/IP™/Modbus® TCP 5 = DeviceNet™ 6 = PROFIBUS DP C = 6 digital I/O (not available on îfc DIN models) D = 6 digital I/O and EIA 485 Modbus® RTU (not available on îfc DIN models) Auxiliary Control Functions A = None C = 2nd PID channel with universal input - not available on î& DIN models J = 2nd PID channel with thermistor input - not available on î/6 DIN models R = Auxillary 2nd input (universal input) P = Auxillary 2nd input (thermistor input) T = Current transformer input (not valid Output 3 and 4 selections = FA, FC, FJ and FK) L = Integrated limit controller with universal input (only valid Output 3 and 4 selections = CJ, EJ and AJ M = Integrated limit controller with thermistor input (only valid Output 3 and 4 selections = CJ, EJ and AJ îfc DIN Models: If communication options 2 thru 6 is ordered in previous digit, then Option A must be ordered here. îfc DIN Models: Auxiliary input supports remote set point and backup sensor. Î8 DIN and Î4 DIN Models: Auxiliary input supports remote set point, backup sensor ratio, differential and wet-bulb/dry-bulb input. ©© Output 3 and 4 Hardware Options Output 3 Output 4 AA = None None AJ = None Mechanical relay 5A, Form A AK = None SSR Form A, 0.5A CA = Switched dc/open collector None CC = Switched dc/open collector Switched dc CH = Switched dc/open collector NO-ARC 15A power control CJ = Switched dc/open collector Mechanical relay 5A, Form A CK = Switched dc/open collector SSR Form A, 0.5A EA = Mechanical relay 5A, Form C None EC = Mechanical relay 5A, Form C Switched dc EH = Mechanical relay 5A, Form C NO-ARC 15A power control EJ = Mechanical relay 5A, Form C Mechanical relay 5A, Form A EK = Mechanical relay 5A, Form C SSR Form A, 0.5A FA = Universal process None FC = Universal process Switched dc FJ = Universal process Mechanical relay 5A, Form A FK = Universal process SSR Form A, 0.5A KH = SSR Form A, 0.5A NO-ARC 15A power control KK = SSR Form A, 0.5A SSR Form A, 0.5A îfc DIN Models: If communication options 2 thru 6 is ordered in previous digit, then Option AA must be ordered here. J/6 DIN Models: Output options CH, EH and KH are not valid. © Additional Options A = Standard C = Enhanced firmware which includes compressor control, cascade, ratio, differential, square-root and motorized valve control without feedback. Option not available with î/6 DIN (PM6) © ® Custom Options AA = Standard EZ-ZONE PM face plate 12 = Class 1, Div. 2 (not available with integrated limit Option "L" or "M", or with Output types E, H, or J) WATLOW® 245
|