A T
O
W
SERV-RITE Wire and Cable
Thermocouple Wire
PVC Insulated and Shielded Thermocouple and Extension Wire SERIES 510
Popular Constructions
Grade
AWG
Wire Type
Limits of Error
Type K
Type J
Type T
Extension
16
Solid
Standard
K16-5-510
J16-5-510
T16-5-510
Stranded
Standard
K16-7-510
J16-7-510
T16-7-510
20
Solid
Standard
K20-5-510
J20-5-510
T20-5-510
Stranded
Standard
K20-7-510
J20-7-510
T20-7-510
24
Solid
Standard
K24-5-510
J24-5-510
T24-5-510
Stranded
Standard
K24-7-510
J24-7-510
T24-7-510
Grade
AWG
Wire
Limits of
Type E
Type S
Type
Error
Extension
20
Solid
Standard
E20-5-510
S20-5-510
Note: Bolded products are stocked and shipped in 100, 250, 500 and 1000 foot spools.
The SERIES 510 is a PVC insulated, twisted and shielded construction for systems sensitive to induced voltages and "noise." SERIES 510 (see page 202) is also available as UL® listed PLTC.
The conductors are insulated with color coded PVC. The next operation twists the two insulated conductors with a copper drain wire. An alumin-ized polyester tape is wrapped around the wires to impart 100 percent shielding. Lastly, another layer of PVC is applied.
The twisting eliminates most EMI while the shield tape minimizes AC "noise".
Available Constructions
1 2 3 4 5 6 7 --5 1 0
1. ASTM E 230 Calibrations-
BE K S
CJ N T
2-3. AWG-
24 20
24 stranded (7/32) 20 stranded (7/28)
4. Conductor Type/Tolerance-
16
16 stranded (7/24)
14
14 stranded (7/22)
Thermocouple grade, solid wire, standard tolerance Thermocouple grade, solid wire, special tolerance Thermocouple grade, stranded wire, standard tolerance Thermocouple grade, stranded wire, special tolerance Extension grade, solid wire, standard tolerance Extension grade, solid wire, special tolerance Extension grade, stranded wire, standard tolerance Extension grade, stranded wire, special tolerance
Note: Minimum order sizes apply for non-stock constructions.
Continuous Use T
Single Use
Temp.
Temp.
• Available with optional metallic overbraid for additional abrasion resistance
Applications
• General use extension wire
Performance Capabilities
• Continuous temperature rating 105°C (220°F)
• Flexible PVC plastic insulation
• Twisted and shielded construction to reduce electrical noise interference
105°C (220°F) 105°C (220°F)
Resistance Properties
Moisture Chemical
Abrasion
Excellent Good
Good
m
3J
T m
®
Wire Specifications
Nominal Insulation Thickness
Nominal Overall
Approximate
Nominal Conductor Size
Conductor
Overall
Size
Shipping Weight
IH
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
lbs/1000 ft
(kg/km)
24
0.020
(0.508)
0.015
(0.381)
0.020
(0.508)
0.140
(3.56)
13
(19.4)
24 S* (7/32)
0.024
(0.610)
0.015
(0.381)
0.020
(0.508)
0.148
(3.76)
14
(20.9)
20
0.032
(0.813)
0.015
(0.381)
0.020
(0.508)
0.164
(4.17)
22
(32.8)
20 S* (7/28)
0.038
(0.965)
0.015
(0.381)
0.020
(0.508)
0.176
(4.47)
24
(35.8)
18
0.040
(1.02)
0.020
(0.508)
0.020
(0.508)
0.200
(5.08)
30
(44.7)
18 S* (7/26)
0.048
(1.22)
0.020
(0.508)
0.020
(0.508)
0.216
(5.49)
32
(47.7)
16
0.051
(1.29)
0.020
(0.508)
0.020
(0.508)
0.222
(5.64)
39
(58.1)
16 S* (7/24)
0.060
(1.52)
0.020
(0.508)
0.020
(0.508)
0.240
(6.10)
41
(61.1)
14
0.064
(1.63)
0.020
(0.508)
0.025
(0.635)
0.258
(6.55)
55
(82.0)
14 S* (7/22)
0.076
(1.93)
0.020
(0.508)
0.025
(0.635)
0.282
(7.16)
58
(86.4)
i
IV Q.
o
0)
* "S" denotes stranded wire: e.g., "24 S (7/32)" is seven strands of 32 gauge wire to make a 24 gauge stranded conductor.
201

pageCatalog pdf di En 2012-02-06-12