| | | A T | | O | | W | | |
| | | |
| | | SERV-RITE Wire and Cable | | |
| | | |
| | | Thermocouple Wire PVC Insulated and Shielded Thermocouple and Extension Wire SERIES 510 | | |
| | | Popular Constructions | | |
| | | |
| | | | | | | | | | | | | | | Grade | AWG | Wire Type | Limits of Error | Type K | Type J | Type T | | | | Extension | 16 | Solid | Standard | K16-5-510 | J16-5-510 | T16-5-510 | | | | Stranded | Standard | K16-7-510 | J16-7-510 | T16-7-510 | | | | 20 | Solid | Standard | K20-5-510 | J20-5-510 | T20-5-510 | | | | Stranded | Standard | K20-7-510 | J20-7-510 | T20-7-510 | | | | 24 | Solid | Standard | K24-5-510 | J24-5-510 | T24-5-510 | | | | Stranded | Standard | K24-7-510 | J24-7-510 | T24-7-510 | | | | | | | | | | | | | | |
| | | |
| | | |
| | | | | | | | | | | | | | | Grade | AWG | Wire | Limits of | Type E | Type S | | | | | | | Type | Error | | | | | | | Extension | 20 | Solid | Standard | E20-5-510 | S20-5-510 | | | | | | | | | | | | | | |
| | | |
| | | Note: Bolded products are stocked and shipped in 100, 250, 500 and 1000 foot spools. | | |
| | | |
| | | The SERIES 510 is a PVC insulated, twisted and shielded construction for systems sensitive to induced voltages and "noise." SERIES 510 (see page 202) is also available as UL® listed PLTC. The conductors are insulated with color coded PVC. The next operation twists the two insulated conductors with a copper drain wire. An alumin-ized polyester tape is wrapped around the wires to impart 100 percent shielding. Lastly, another layer of PVC is applied. The twisting eliminates most EMI while the shield tape minimizes AC "noise". | | |
| | | Available Constructions | | |
| | | 1 2 3 4 5 6 7 --5 1 0 | | |
| | | |
| | | |
| | | 1. ASTM E 230 Calibrations- BE K S CJ N T 2-3. AWG- 24 20 24 stranded (7/32) 20 stranded (7/28) 4. Conductor Type/Tolerance- | | |
| | | 16 16 stranded (7/24) | | 14 14 stranded (7/22) | | |
| | | |
| | | |
| | | Thermocouple grade, solid wire, standard tolerance Thermocouple grade, solid wire, special tolerance Thermocouple grade, stranded wire, standard tolerance Thermocouple grade, stranded wire, special tolerance Extension grade, solid wire, standard tolerance Extension grade, solid wire, special tolerance Extension grade, stranded wire, standard tolerance Extension grade, stranded wire, special tolerance Note: Minimum order sizes apply for non-stock constructions. | | |
| | | |
| | | | | | | | | | Continuous Use T | Single Use | | | | Temp. | Temp. | | | | | | | | | |
| | | |
| | | • Available with optional metallic overbraid for additional abrasion resistance Applications • General use extension wire | | |
| | | Performance Capabilities • Continuous temperature rating 105°C (220°F) • Flexible PVC plastic insulation • Twisted and shielded construction to reduce electrical noise interference | | |
| | | |
| | | 105°C (220°F) 105°C (220°F) | | |
| | | | | | | | | | Resistance Properties | | | | Moisture Chemical | Abrasion | | | | Excellent Good | Good | | | | | | | | | |
| | | m 3J T m ® | | |
| | | |
| | | |
| | | |
| | | Wire Specifications | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | Nominal Insulation Thickness | Nominal Overall | Approximate | | | | | Nominal Conductor Size | Conductor | Overall | Size | | Shipping Weight | | | | IH | in. | (mm) | in. | (mm) | in. | (mm) | in. | (mm) | lbs/1000 ft | (kg/km) | | | | 24 | 0.020 | (0.508) | 0.015 | (0.381) | 0.020 | (0.508) | 0.140 | (3.56) | 13 | (19.4) | | | | 24 S* (7/32) | 0.024 | (0.610) | 0.015 | (0.381) | 0.020 | (0.508) | 0.148 | (3.76) | 14 | (20.9) | | | | 20 | 0.032 | (0.813) | 0.015 | (0.381) | 0.020 | (0.508) | 0.164 | (4.17) | 22 | (32.8) | | | | 20 S* (7/28) | 0.038 | (0.965) | 0.015 | (0.381) | 0.020 | (0.508) | 0.176 | (4.47) | 24 | (35.8) | | | | 18 | 0.040 | (1.02) | 0.020 | (0.508) | 0.020 | (0.508) | 0.200 | (5.08) | 30 | (44.7) | | | | 18 S* (7/26) | 0.048 | (1.22) | 0.020 | (0.508) | 0.020 | (0.508) | 0.216 | (5.49) | 32 | (47.7) | | | | 16 | 0.051 | (1.29) | 0.020 | (0.508) | 0.020 | (0.508) | 0.222 | (5.64) | 39 | (58.1) | | | | 16 S* (7/24) | 0.060 | (1.52) | 0.020 | (0.508) | 0.020 | (0.508) | 0.240 | (6.10) | 41 | (61.1) | | | | 14 | 0.064 | (1.63) | 0.020 | (0.508) | 0.025 | (0.635) | 0.258 | (6.55) | 55 | (82.0) | | | | 14 S* (7/22) | 0.076 | (1.93) | 0.020 | (0.508) | 0.025 | (0.635) | 0.282 | (7.16) | 58 | (86.4) | | | | | | | | | | | | | | | | | | |
| | | i IV Q. | | |
| | | |
| | | o 0) | | |
| | | |
| | | |
| | | * "S" denotes stranded wire: e.g., "24 S (7/32)" is seven strands of 32 gauge wire to make a 24 gauge stranded conductor. | | |
| | | 201 | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |