W A T L O W
Barrel Heaters
THINBAND Mica
Type K Type KR >
Barrel Heater Terminations
Stock LA Option Stock LA Option Continued
Two fiberglass lead wires exit a single tightly woven metal braid for
good abrasion protection, lead flexibility and wiring convenience.Leads are 51 mm (2 in.) longer thanthe braid. To order, specify Å (ac) use this wire. Heaters rated at less than 250 volts
use UL >
® approved lead insulationfor operations to 250ËšC (482ËšF) as
standard.Lead insulation UL >
® ratedfor operation to 450ËšC (850ËšF) may
be required in high temperature
applications where the leads are
shrouded or enclosed with the
heater. All heaters rated at more
than 250V Flexible lead wires exit verticallyfrom the heater. These leads can bebent adjacent to the heater for a
quick and easy connection. To order, specify Same specifications as Type Kexcept lead wires exit at right angle.
To order, specify TypeKR andlength.
Same specifications as Type Cexcept lead wires exit at right angle.
To order, specify Type K and length. Type C Type BR >
Injection moulding machine Barrel Heaters Stock LA Option Stock LA Option TypeBR andlength. Type C and length. Type F Type FR Stock LA Option Stock LA Option Type F and length. Loose fiberglass sleeving enclosestwo fiberglass leads for additional
insulation protection where high temperature or minor abrasion is
present. Leads are 51 mm (2 in.)
longer than the sleeving. To order,
specify Same specifications as Type Fexcept lead wires exit at right angle.
To order, specify TypeFR andlength. See page 38 forminimum/maximumdimensional requirements. 43 >