| | | Performance data as guidelines for CHP calculations Wartsila gas fuelled generating sets at 50 and 60 Hz Engine 9L34SG 16V34SG | | |
| | | |
| | | | | | | | | | | | | | | | Frequency | | Hz | 50 60 | 50 | 60 | 50 60 | 50 60 | | | | Engine optimization: NOX (dry @ 5 vol-% O2) | | mg/ Nm3 | 250 250 | 500 | 500 | 250 250 | 500 500 | | | | Electric power | | kW | 3888 3758 | 3888 | 3758 | 6970 6737 | 6970 6737 | | | | Heat rate 1) | | kJ/kWh | 8065 8065 | 7817 | 7817 | 7999 7999 | 7753 7753 | | | | Electrical efficiency 1) | | % | 44.6 44.6 | 46.1 | 46.1 | 45.0 45.0 | 46.4 46.4 | | | | Engine cooling water circuit 2) | | °C | 38/67 38/66 | 38/65 38/64 38/69 38/68 38/67 38/66 | | | | Engine cooling water circuit, heat power | ± 10% | kW | 2012 1942 | 1894 | 1832 | 3558 3451 | 3357 3252 | | | | High-temperature charge air cooler, water 2) | | °C | 46/60 46/59 | 46/58 45/57 47/61 47/60 47/59 46/58 | | | | High-temperature charge air cooler, heat power | ± 10% | kW | 948 924 | 839 | 817 | 1614 1576 | 1432 1395 | | | | Jacket cooling water 2) | | °C | 86/91 86/91 | 86/91 86/91 | 86/91 86/91 | 86/91 86/91 | | | | Jacket cooling, heat power | ± 10% | kW | 504 486 | 513 | 495 | 890 860 | 910 880 | | | | Lubricating oil 2) | | °C | 63/71 63/70 | 63/71 63/71 | 63/73 63/72 63/73 63/72 | | | | Lubricating oil, heat power | ± 10% | kW | 414 396 | 419 | 405 | 730 710 | 740 720 | | | | Low-temperature charge air cooler, water 2) | | °C | 38/40 38/40 | 38/40 38/40 38/41 38/41 | 38/40 38/40 | | | | Low-temperature charge air cooler, heat power | ± 10% | kW | 146 136 | 123 | 115 | 324 305 | 275 257 | | | | Charge air flow | ± 5% | kg/s | 6.9 6.7 | 6.4 | 6.2 | 12.3 11.9 | 11.5 11.1 | | | | Exhaust gas flow | ± 5% | kg/s | 7.1 6.8 | 6.6 | 6.4 | 12.6 12.2 | 11.8 11.4 | | | | Exhaust gas temperature | ± 10°C | °C | 375 375 | 390 | 390 | 375 375 | 390 390 | | | | Exhaust gas heat power 3) | ± 10% | kW | 2976 2878 | 2813 | 2719 | 5302 5117 | 5013 4843 | | | | Heat power losses by radiation | ± 15% | kW | 270 263 | 270 | 261 | 430 413 | 420 403 | | | | | | | | | | | | | | | |
| | | |
| | | Note: Heat and mass balances dependend of ambient conditions and plant application. The above figures are for guidance only and calculated at ISO 3046-1 standard reference conditions: 25°C ambient temperature. 100 kPa total barometric pressure. 30% relative humidity. Charge air coolant temperature according to tabulated data. Natural gas (Lower Heating Value 35300 kJ/Nm3). Gas Methane Number >80. LFO (Lower Heating Value 42700 kJ/kg). Nm3 defined at NTP (273.15 K and 101.3 kPa) | | |
| | | |
| | | 24 | | |
| | | |
| | | | | | | | | | |