GAS POWER PLANTS
GAS ENGINES
1 WÄRTSILÄ
34SG
Technical data 50 Hz/750 rpm
Unit
9L34SG
16V34SG
20V34SG
Power, electrical
kW
3888
6970
8730
Heat rate
kJ/kWh
7817
7753
7737
Electrical efficiency
%
46.1
46.4
46.5
Technical data 60 Hz/720 rpm
Power, electrical
kW
3758
6737
8439
Heat rate
kJ/kWh
7817
7753
7737
Electrical efficiency
%
46.1
46.4
46.5
Dimensions and weight (generating set with liquids and 150 mm high spring elements)
Length
mm
10937
11692
12666
Width
mm
2550
3233
3300
Height
mm
3856
4348
4646
Weight
tonne
81
115
137
Heat rate and electrical efficiency at generator terminals, including engine-driven pumps. ISO 3046 conditions and LHV.
Tolerance 5%. Power factor 0.8. Gas Methane Number >80.
DUAL-FUEL ENGINES
WÄRTSILÄ
Technical data 50 Hz/750 rpm
Unit
18V32DF
18V32DF*
Power, electrical
kW
6080
6080
Heat rate
kJ/kWh
8074
8201
Electrical efficiency
%
44.6
43.9
Technical data 60 Hz/720rpm
Power, electrical
kW
5819
5819
Heat rate
kJ/kWh
8074
8201
Electrical efficiency
%
446
43.9
Dimensions and weight (generating set with liquids and 150 mm high spring elements)
Length
mm
11318
11318
Width
mm
3454
3454
Height
mm
4364
4364
Weight
tonne
102
102
Heat rate and electrical efficiency at generator terminals, including engine-dri\ conditions and LHV.
Tolerance 5%. Power factor 0.8. Gas Methane Number >80. *) In LFO mode.
i pumps, ISO 3046
10