Leak Detection Operating Principle

Electronic Leak Detection Visual Leak Detection

How electronic leak How visual leak detection works. detection works.

At a point the pumping At a point the pumping diaphragm fails, pumped

Chamber filled with driver fluid liquid enters the spill

Chamber filled with driver fluid diaphragm fails, pumped liquid enters chamber displacing
Outer the spill chamber,
Outer Pumping driver fluid. e leak
Pumping Chamber detector, working on the
Chamber displacing driver

principle of conductance,

fluid. e exchange of pumpage and driver senses the conductivity fluid displays a color change. is activates change in the sight tube, a warning light on the giving a visible signal. control box. e device Driver fluid should be can also be wired into chemically compatible the pump user’s existing with the pumped

system, for an audible
Pumping diaphragm or visual alarm, or pump

fluid, with an obvious
Pumping difference in color. In shut-down response. It
diaphragm

is important to specify

the event a leak occurs,
Clear pumpage is contained
Driver an appropriate drive
site tube in the spill chamber.
diaphragm fluid which is both chemically compatible

e pump will continue
Driver with the pumped fluid
diaphragm to work, and in many cases, repairs can be and displays the opposite done when the batch is conductance properties. completed. e air valve Polarity of the leak and work environment detector can be set to are protected. sense conductive or non-conductive fluid. If a leak occurs, pumpage is contained in the spill chamber. e pump will continue to work, and in many cases, repairs can be done when the batch is completed. e air valve and work environment are protected. ELECTRONIC LEAK DETECTOR: Working VISUAL LEAK DETECTOR: A sight tube MECHANICAL LEAK DETECTOR: When on the principle of conductance, this monitor style leak detector is installed on each a leak chemically attacks an internal o-ring can be wired for visual, audible or pump shut- driver chamber. If a pumping diaphragm on this detector, it actuates a plunger. is down response. e electronic leak detector break occurs, liquid in the sight tube opens an air valve, which in turn activates is an optional accessory which can be installed changes color. a customer-supplied solenoid (or similar on all models. device) to trigger a signal.

www.warrenrupp.com 41