WANDFLUH
Hydraulics+ Electronics
|
|
|
|
|
|
|
|
|
|
|
CHARACTERISTICS Oil viscosity v = 30 mm2/s
p = f (Q) Performance limits at 10% under voltage and
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
p [bar] max. ambient temperature
|
|
|
|
oou 300 250 200 150 100 50 0
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 15 30 45 60 75 90 105 120 Q [l/min]
|
|
|
|
|
|
|
|
|
Ap = f (Q) Pressure volume flow characteristics [DC / CD] Ap [bar]
|
|
|
|
Construction Switching solenoid, wet pin pull- or push
type, pressure tight Standard nominal voltage: UN = 12 VDC, 24 VDC
UN = 110 VAC*, 115 VAC*, 230 VAC*
AC = 50 up 60 Hz
- * Rectifier integrated in connector socket
- Other nominal voltages and wattages on request Voltage tolerance ±10% of nominal voltage Protection class IP 65 acc. to EN 60 529
(if correctly mounted)
Relative duty cycle 100% DF (see data sheet 1.1-430)
Switching cycles 5'000/h
Operating life 107 (number of switching cycles, theoretically)
Connections/Power supply Versions see type code Solenoid type:
- Steel coil (M.35/16) data sheet 1.1-170
- Plastic coil (K.35/16) data sheet 1.1-172
|
|
|
|
|
|
|
|
|
0 15 30 45 60 75 90 105 120 Q [l/min]
|
|
|
|
Ap = f (Q) Pressure volume flow characteristics [BA / AB] Ap [bar]
|
|
|
|
|
|
|
|
|
|
CAVITY
Cavity drawing to
ISO 7789-33-01-0-98
|
|
|
|
0 15 30 45 60 75 90 105 120 Q [l/min]
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
For detailed cavity drawing and cavity tools see data sheet 2.13-1005
|
|
|
|
|
|
|
|
Wandfluh AG Postfach
CH-3714 Frutigen
|
|
Illustrations not obligatory Data subject to change
|
Data sheet no. 1.11-20 E 2/3