WANDFLUH
Hydraulics+ Electronics
|
Amplifier / controller electronics
|
|
|
|
|
|
|
|
Control through CANopen interface with amplifier electronics
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
^ I / I Solenoid A IA/D I-j-1
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
I—y—, Solenoid B
I / I (only for valve with 2 solenoids)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
^ X2-2 —i>—-o
L X2-3 RS232 i '—4-o
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ELECTRICAL SPECIFICATIONS
|
|
|
|
|
|
|
|
|
IP 67 acc. to EN 60 529
With suitable connector and closed
electronics housing cover
M12, 4-poles (male)
M12, 5-poles (male) acc. to DRP303-1
24 VDC or 12 VDC
21...30 V 10,5...15 V <10 % slow
50 mA
Imax = 1000 mA (with version 24 VDC) Imax = 2000 mA (with version 12 VDC) Imax = 1200 mA (with version 24 VDC) Imax = 2400 mA (with version 12 VDC)
|
Preset value signal CANopen interface
Bus topology Separation of potential Ramps adjustable Temperature drift Setting parameters Serial interface
|
via CANopen
Two wire lead acc. to ISO 11898 Differential signal transmission Line
CANopen to „DSV" electronics 500 VDC
0.51 s
<1 % at AT = 40 °C via CANopen or RS 232 C RS 232 C (Receptacle RJ10) to set parameters with „PASO"
under cover of electronic housing settings adjusted at factory
EN 61 000-6-2 EN 61 000-6-4
|
|
|
|
Réceptacle for supply Receptaclfe for CANopen Supply voltage Voltage range:
• 24 VDC
• 12VDC
Ripple on supply voltage
Fuse
Current consumption:
• No load current
• 35 mm square size solenoid
• 45 mm square size solenoid
|
|
|
|
|
|
|
|
|
|
|
|
Wandfluh AG Postfach
CH-3714 Frutigen
|
|
Illustrations not obligatory Data subject to change
|
Data sheet no. 1.13-75E 6/11 Edition 06 26
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|