WANDFLUH
Hydraulics+ Electronics
Amplifier / controller electronics
Control through analog interface with amplifier electronics
BLOCK DIAGRAM
Supply-voltage
rPWM
Solenoid A
Microcontroller
Stabilised output 0 voltage
[ÂTÎT
Preset value 1 Voltage X1-5
I PWM
Solenoid B
(only for valve with 2 solenoids)
X1-6
Preset value 2 +0 rT"1"^ Current X1-7 U
- o- T [
X1-11
Digital input
X1-10
>
-o Digital output
FEPROM
RAM
X2-2 -o
Châssis
X1-12
EEPROM
X2-3 RS232
~?H
X2-1
ELECTRICAL SPECIFICATIONS
Protection class
Réceptacle Plug
Supply voltage Voltage range:
• 24 VDC
• 12VDC
Ripple on supply voltage
Fuse
Current consumption:
• No load current
• 35 mm square size solenoid
• 45 mm square size solenoid
Preset value signal:
IP 67 acc. to EN 60 529 With suitable connector and closed electronics housing cover M23, 12-poles (male)
M23, 12-poles (female) (not incl. in the delivery)
24 VDC or 12 VDC
21. ..30 V 10,5...15 V <10 % slow
ca. 40 mA
Imax = 1000 mA (with version 24 VDC) Imax = 2000 mA (with version 12 VDC) Imax = 1200 mA (with version 24 VDC) Imax = 2400 mA (with version 12 VDC)
Selectable with software Diff. inputs not galvanically separated, for earth potential differences up to 1,5 V 4...+20 mA / 0...+20 mA
0... + 10 V (1- or 2-solenoid valve) -10.. .+10 V (only 2-solenoid valve)
Input resistance
Stabilised output voltage
Digital inputs
Digital output
Voltage input >18 kQ
Load for current input = 250 Q
10 VDC (with version 24 VDC) 8 VDC (with version 12 VDC)
max. load 10 mA
Switching threshold high 6.30 VDC Switching threshold low 0.1 VDC Low-Side-Switch: Umax = 40 VDC
Imax = -700 mA 0.51 s
<1 % at AT = 40 °C
RS 232 C (Receptacle RJ10)
to set parameters with „PASO"
under cover of electronic housing settings adjusted at factory
EN 61 000-6-2 EN 61 000-6-4
Ramps adjustable Temperature drift Serial interface
EMV
Immunity Emission
Wandfluh AG Postfach
CH-3714 Frutigen
Tel. +41 33 672 72 72 E-mail: sales@wandfluh.com Fax +41 33 672 72 12 Internet: www.wandfluh.com
Illustrations not obligatory Data subject to change
Data sheet no. 1.13-75E 2/11 Edition 06 26