WANDFLUH
Hydraulics+ Electronics
Description
corrosion- and explosion protection
Description explosion protection Guideline 94/9/EG (ATEX)
Appliances and protection Systems for the purpose of being used in areas subject to explosion hazard.
Fields of Application
Group II
Electric operating equipment for all areas subject to explosion hazard,
with the exception of underground (mine) workings subject to fire-damp hazard
Electric operating equipment for underground (mine) workings subject to fire-damp hazard (Devices for this field of application are not available from Wandfluh)
Group I
Zone 0 (for G)
Encompasses areas, in which a hazardous atmosphere capable of exploding is continuously present or present over a long time period. For this zone, devices of the category 1 are necessary.
Encompasses areas, in which it has to be anticipated, that a hazardous atmosphere capable of exploding is present occasionally. For this zone, devices of the category 2 (or 1) are necessary.
Encompasses areas, in which it has to be anticipated, that a hazardous atmosphere capable of exploding is present only rarely and then only for a very short time period. For this zone, devices of the category 3 (or 1 resp. 2) are necessary.
Encompasses areas, in which an atmosphere capable of exploding is present continuously, for a long time period or frequently in the form of a cloud consisting of inflammable dust in the air. For this zone, devices of the category 1 are necessary.
Encompasses areas, in which during normal operation an atmosphere capable of exploding occasionally may occur in the form of a cloud consisting of dust in the air. For this zone, devices of the category 2 (or 1) are necessary.
Encompasses areas, in which during normal operation an atmosphere capable of exploding is not normally present or only for a short time period in the form of a cloud consisting of inflammable dust in the air. For this zone, devices of the category 3 (or 1 resp. 2) are necessary.
Zone 1 (for G)
Zone 2 (for G)
Zone 20 (for D)
Zone 21 (for D)
Zone 22 (for D)
G (for group II) D (for group II) M (for group I)
Gas-, steam- / vapour-, mist- and air mixtures Dust
Underground (mine) workings (not available from Wandfluh)
Wandfluh AG Tel. +41 33 672 72 72 E-mail: sales@wandfluh.com Illustrations not obligatory Page 3
Postfach Fax +41 33 672 72 12 Internet: www.wandfluh.com Data subject to change Edition 06 39

pageCatalog pdf di En 2012-06-22-01