Hitachi RPK Wall Mounted - Walter Meier (Klima International) AG - #1

/ 1


catalogue search
Hitachi RPK Wall Mounted - Walter Meier (Klima International) AG
P. 01
Page:
Hitachi RPK Wall Mounted - Walter Meier (Klima International) AG


See other catalogues for Walter Meier (Klima International) AG

Text version of the page
HITACHI HIGH WALL UTOPIA
■ Elegant design
Cooling kW 5.00 to 10.00 Heating kW 5.60 to 11.20
RPKWALL MOUNTED
Extended line-up
Quiet operation
Mprecampactthan previous models
R410A refrigerant
I indoor Unit Technical Data 1
Mode!
RPK-2 FSN2M
RPK-2.5FSN2M
RPK-3FSN2M
RPK-4FSN2M
RPMFSW2M
Cooling (kW) - Nominal
5,00
630
7.10
10.00
10.00
Heating [!<W] - Nominal
5.60
7.00
8.00
11.20
11.20
Cooling (kW) - UK Condition
5.35
5.92
7.54
10.54
10.54
Heating [kW] - UK Condition
6 30
6.15
8.89
12.55
12.55
Sensible Heat Ratio (SHR)
0.72
0.72
0.71
0,71
0.71
Sound Pressure - Std SP (dBA)
41/39/37
43/40/37
43/40/37
49/46/43
49/46/43
Height (mm)
2 '35
333
333
333
333
Width [mm]
1030
1150
1150
1150,
1150
Depth [mm]
208
245
245
245
245
Weight (kg)
12
IS
18
18
18
Air Flow Rate - Std SP (m'/min)
14/12/10
17/16/14
17/16/14
22/20A7
22/20/17
1 Outdoor Unii Technical Data f
Model
Height (mm)
RAS2HVRN1
600
RAS-2.5HVRN3
600
RAS-3HVRNE
800
RAS-4HVRNE
1240
RAS 4HRNL
1240
Width (mm)
792
792
850
950
950
Depth (mm)
300
300
315
315
315
Weight (kg)
42
42
60
95
100
Airflow (mVmtn)
35
35
45
SO
80
Sound Pressure (dBA)
-•'■6
46
"■3
45
45
Sound Pressure - Set Back [dBA)
44
44
39
41
41
Liquid - mm (inches)
6.35 (1/4)
6.35 (1/4)
9.52 [3/S)
9.52 (3/8)
9.52 (3/8)
Gas-mm (inches)
12.70 (1/2)
12.70 (1/2)
15,88 (5/8)
15,88 (5/8)
15.88 (5/8)
Max Pipe Run (m)
50
50
60
77
77
Max Pipe Lift (m)
30
30
30
30
30
Pre-charged to(m)
30
30
30
30
30
Sta nding Charge (kg)
1.6
1.6
2.4
3.6
3.6
Refrigerant
P.410A
R410A
R410A
R410A
R410A
Phase
Single
5lngle
Single
Single
Three
Power Supply to
Outdoor '
Outdoor *
Outdoor '
Outdoor '
Outdoor '
Max Cu Trent (A)
13
16
21
28
15
Fuse Rating (A)
16
20
25
32
16
Interconnecting
LNE + 2 '
LNE + 2 '
LNE - 2 '
LNE + 2 '
LNE + 2'
H-Link Compatible
Yes
Yes
Yes
Yes
Yes
E CA Approved
Pending
Pending
Pending
Pending
Pending
Energy Rating (Cool/Heat)
A/A
A/A
A/A
A/A
A/A
EER
3,57
3,41
3.42
3,65
3.65
COP
3.81
4.02
.3.90
4.16
4.16
' Note: Power can be supplied either from outdoor unit (via iocal fused Isolator) or separately. Interconnecting wiring should be LNE + 2 core screened comms cable if mains power is to outdoor unit only or 2 core screened comms cable only If power supply Is to both indoor and outdoor units.
U.K. Cool
U.K; Heat
Operating Conditions
Norn. Cool
Nom. Heat
Indoor Air Inlet Temperature
DE
27.00
20,00
23.00
22.00
WE
19,00
16.00
Outdoor Air Inlet Temperature
□ B
35.00
/.00
30.00
WB
6.00
000
Piping Length; 7.5 metres: Piping Lift: 0 metres. DB: Dry Bulb: WB; Wet Bulb.
Information as advertised In Hitachi Technical Catalogue TCARC003_1 -05/07 or other equivalent source where data was not available. Walter Meier (Climate UK) Ltd cannot be held responsible for any errors in the above Information.
waiter Meier
Walter Meier (Climate UK) Ltd.
Highlands Road, Shirley, Solihull, West Midlands B90 4NL Tel: 0871 663 0664, Fax: 0871 663 1664 uk.climate@waltermeier.com www.waltermeier.com

pageCatalog pdf di En 2012-06-22-01