Hitachi RAI 600mm² Mini Cassette - Walter Meier (Klima International) AG - #1

/ 1


catalogue search
Hitachi RAI 600mm² Mini Cassette - Walter Meier (Klima International) AG
P. 01
Page:
Hitachi RAI 600mm² Mini Cassette - Walter Meier (Klima International) AG


See other catalogues for Walter Meier (Klima International) AG

Text version of the page
HITACHI CASSETTE RAC/MONOZONE
RAI 600mm2 MINICASSETTE
Fits into 600mm2 ceiling tile space
Low noise level just 25dBA Flexible airflow system
■ Built in drain pump
■ One-touch panel
Cooling kW 2.S0 to 5.00 Heating kW 3.50 to 6.50
R410A
refrigerant
I Itïdom Unit Technical Pala j
Model
RAI-25NH5
RAI-3SNH5
RAI-50NH5
Cooling (kW) - Nominal
2.50
3.50
5.00
Heating (kW) - Nominal
3.50
4.80
6.50
Cooling (kW) - UK Condition
2.34
2.76
3.17
Heating (kW)-UKCondition
2.91
3,99
5.40
Sensible Cooling Duty (UK)
1.82
2,22
2.30
Sour!J Pressure ■ Coo irsg (dBA)
35/32/29
39/34/29
43/35/32
Sound Pressure - Heating (dBA)
36/33/30
40/36/32
-lì/36/32
Height (mm)
285
285
285
Width-mm (Grille)
580 (650)
580 (650)
580 (650)
Depth - mm (Grille)
580(650}
580(650)
580 (650)
Weight-kg(Grille)
20(4)
20 (4)
20(4)
Air Flow - Cooling (m'/min)
8,5/7,0/5.8
10,8/8,0/S.B
12.0/8 0/5-S
Air Flow - Heating (m'/min)
8.5/7.0/5.S
10,8/8.0/5,8
12.0/8.0/5.8
Outdoor Unii Tethnicat Data
Model
RAC-2SNH5
RAC-3SNHS
RAC-50NHS
: leiglit {mm!
570
570
650
Width (mm) Depth (mm) Weight (kg;
750
750
850
280
280
29S
38
38
45
Sound Pressure - Cooling (dBA)
50
4-5
47
Sound Pressure - Heating (dBA)
46
49
52
6.35(1/4)
Liquid -mm (inches)
6.35 (1/4)
6.35 ¡1/4)
G3S- mm (inches)
9.52 (3/8)
9.52 (3/8)
12.70 (1/2)
Max Pipe Run (m)
20
20
20
Max Pipe Lift (m)
10
10
10
Pre-charged to (m)
20
20
20
Standing Charge (kg)
1.15
1.15
1.40
Refrigerant
R410A
K410A
R410A
Phase
Single
Single
Single
Power Supply to
Outdoor
Outdoor
Outdoor
Starting Current (A) Fuse Rating (A)
4.20
4.20
10.00
16
16
16
Interconnecting
2C + E'
2C + E*
2C + E*
H LinkCompatible
No
No
No
ECA Approved
Yes
Yes
No
Energy Rating (Cool/Heat)
A/A
B/B
E/D
EER
3.60
3.18
2.51
COP
3.72
3.53
3.01
■ Note: Power is to outdoor unit via local fused Isolator, interconnecting wiring is 1.5mm 3 Core screened comms cable. Power can be supplied to indoor unit. Please contact Technical Sales for more information on this option.
Operating Conditions
Norn. Cool
Norn. Heat
UK. Cool
U.K. Heat
Indoor Air inlet Temperature
DB
27.00
20.00
22.00
22.00
WB
19.00
16.00
Outdoor Air Inlet Temperature
DB
35.00
7.00
27.00
0,00
WB
6.00
Piping Length; 7.5 metres: Piping Lift: 0 metres. DB: Dry Bulb: WB: Wet Bulb.
Information as advertised in Hitachi Technical Catalogue TCARG003 1 - 05/07 or other equivalent source where data was not available. Walter Meier (Climate UK) Ltd cannot be held responsible for any errors in the above information.
waiter Meier
Walter Meier (Climate UK) Ltd.
Highlands Road, Shirley, Solihull, West Midlands B90 4NL Tel: 0871 663 0664, Fax: 0871 663 1664 uk.climate@waltermeier.com www.waltermeier.com