HITACHI HIGH WALL RAC/SUMMIT
System Air Conditioners -Wall Mounted (Heat Pump)
» New flat framed design
■ DC Inverter PAM Control
■ Highest COPupto4,31 (A) in cooling/430 (A) in heating
RAS SUMMIT SINGLE SPLIT - FH5
■ Low noise down to 20dBA on sleep mode
■ Cooling available under -10°C ambient temperature
■ Heatingavailableevenat -15°C ambient temperature
■ Auto restart and auto changeover
■ Washable carbon and anti-bacteria air purifying filter
■ 24hr remote control timer
Cooling kW 2.50 to 5.00 Heating kW 3.40 to 6.50
R410A . refrigerant
Indoor Unit Technical Data
Mode!
RAS-25FH5
RAS-35FH5
RAS-50FH5
Cooling (kW) - Nominal
2.50
3.50
5.00
Heating (kW) - Nominal
3.40
4.20
6.50
Cooling (kW)-UK Condition
2.50
3.33
3.4S
Heating [fcwj - UK Condition
2.83
3,49
5.40
Sensible Cool ing Duty (UK)
2.11
2.52
2.S6
Sound Pressure -Cooling(dBA)
38/32/26
41/35/29
47/39/28
Sound Pressure - Heating (dBA)
39/33/27
41/35/30
47/39/31
Height (mm)
280
280
280
Width (mm)
780
780
7S0
Depth (mm)
220
220
220
Weight (kg)
9.50
9.50
9.50
Air Flow - Cooling (mVmin)
8.5/7 0/6.0
10,1/8.0/6.5
13.5/10.0/6.8
Air Flow-Heating (mVmlri)
9.5/8.0/7.0
10.8/8.5/7.S
13.5/10.0/6.8
Outdoor Unit Technical Data
Mo!;c-i
RAC-2SYHS
RAC-35YHS RAC-50YH5
Height (mm)
548
548
650
Width (mm)
750
750
850
Depth (mm)
288
288
298
Weight (kg)
35
35
45
Sound Pressure ■ Cooling (dBA)
45
46
50
Sound Pressure - Heating (dBA)
46
47
52
Liquid - mm (inches)
6.35 (1/4)
6.35 (1/4)
6.3S (1/4)
Gas - mm (inches)
9.52 (3/8)
9.52 (3/8)
12.70(1/2)
Max Pipe Run (m)
20
20
20
Max Pipe Lift (m)
10
10
10
Pre-charged to (m)
20
20
2U
Standing Charge (kg)
0.37
0.87
1.40
Refrigerant
R410A
R410A
R410A
Phase
Single
Single
Single
Power Supply to
Outdoor'
Outdoor'
Outdoor"
Starting Current (A)
3.72
4.49
10.00
Fuse Rating (A)
16
16
16
Interconnecting
2C + E1
2C + E*
2C + E'
H-Link Compatible
No
No
No
1 Energy Facts
E CA Approved
Pending
Pending
Pending
Energy Rating (Cool/Heat)
A/A
A/A
c/c
EER
31
3.57
2.81
COP
4,30
4.16
3.30
' Note: Power is to outdoor unit via local fused Isolator. Interconnecting wiring is 1.5mm 3 Core screened comrrts cable Power can also be supplied to indoor unit. Please contact Technical Sales for more information on this option.
Operating Conditions_Norn. Cool_Norn. Heat_U.K. Cool_U.K. Heat
indoor Air inlet Temperature
DB
27.00
20,00
22.00
22.00
WB
19.00
16.00
Outdoor Air Inlet Temperature
DE
Ì5.00
7.00
27.00
0.00
WB
6.00
Piping length; 7.5 metres; Piping Lift: 0 metres. DB: Dry Bulb; WB; Wet Bulb.