Fujitsu ASY Wall Mounted Plasma - Walter Meier (Klima International) AG - #1

/ 1


catalogue search
Fujitsu ASY Wall Mounted Plasma - Walter Meier (Klima International) AG
P. 01
Page:
Fujitsu ASY Wall Mounted Plasma - Walter Meier (Klima International) AG


See other catalogues for Walter Meier (Klima International) AG
You may also be interested in

Cooler, Humidifier, Steam generator, Generator, Steam humidifier


Text version of the page
FUJITSU HIGH WALL PLASMA
WALL MOUNTED (PLASMA)
Washable air filter Slimline construction Cooling/heating Ultra quiet
Long life ion deodorisation filteroptions
Easy-to-use remote controller
Quick and easy installation
■ Plasma filter quickly removes dust particles and odours
Cooling kW 2.60 to 7.10 Heating kW 3.60 to 8.10
—\
R410A
refrigerant
Indoor Unit Technical Data 1
Model
ASYB09LD
ASYB12LD
ASYB18LD
ASYB24LD
CoolingJkW) - Nominal
2.60(0.50-3.70)
3.50(0.90-4.30)
5,2010.90-5,70)_
7.10(2.00-8.00)
Heating (kW) - Nominal
3 60(0. ~,0-6. 10)
4.80(0.90-6.70)
6.2 5 (0.90-9AO)
8.10(2.00-10.00)
Cooling (kW)-UK Condition
Data not available at time of going to press. Please Contact Technical Sales Department.
5.06
6.91
Heating (kW)-UKCondition
7.30
8.S0
Sensible Cooling Duty (UK)
3.26
5.70
Sound Pressure Level (dBA)
39/34/29
41/35/29
45/38/32
47/41/36
Height (mm)
283
283
283
320
Width (mm)
790
790
790
998
DepLh (mm)
230
230
230
228
Weight (kg)
10
10
10
16
Airflow Rate (m'/h)
560
595
700
1100
1
Model
AOYS09LD
AOVS12LD
AOYS18LD
AOYS24LD
Height (mm)
540
540
578
S7S
Width (mm)
790
790
790
790
Depth (mm)
290
290
300
315
Weight (kg)
34
36
40
44
Airflow (m /1)
20&0
1850
2000
2040
Sound Pressure (dBA)
47
47
50
52
Liquid - mm (inches)
6.35 (1/4)
6,35 (1/4)
6.35 (1/4)
6.35 (1/4}
Gas ■ mm (Inches)
9.52 (3/8)
9.52 (3/8)
12.70 (1/2)
15.88 (5/8)
Max Pipe Run (m)
20
20
20
30
Max Pipe Lift (m)
15
15
15
20
Pre-charged to (m)
15
15
15
15
Refrigerant
R410A
R410A
R410A
R410A
Phase
Single
5ingle
S rig e
Single
Power Supply to
Indoor
Indoor
indoor
Outdoor
Fuse Rating (A)
10
10
20
30
Interconnecting
3C+E
3C+E
3C+E
3C+E
Energy Facts 1
ECA Approved
Ye>
Yes
Pending
Yes
Energy Rating (Cool/Heat)
A/A
A/A
BfA
A/A
EES
4.26
3.85
302
3.21
COP
4.44
3.93
J.61
3.62
Operating Conditions_Nom, Cool_Nom. Heat_U.K. Cool_U.K. Heat
Indoor Air inlet Temperature
DB
27.00
20.00
23.00
22.00
WE
19.00
16.00
Outdoor Air Inlet Temperature
DB
35.00
7.00
30,00
0.00
WB
24.00
-2.00
Piping Length: 7.S metres; Piping Lift: 0 metres. DB: Dry Bulb: WB: Wet Bulb.
Information taken from FG Eurofred Limited October 2007 sales literature, data book or other equivalent technical manual where data was not available UK condition source data can vary therefore some UK duties listed above may differ by a small percentage. Walter Meier (Climate UK) Ltd cannot be held responsible for any errors in the above information.
waiter Meier
Walter Meier (Climate UK) Ltd.
Highlands Road, Shirley, Solihull, West Midlands B90 4NL Tel: 0871 663 0664, Fax: 0871 663 1664 uk.climate@waltermeier.com www.waltermeier.com

pageCatalog pdf di En 2012-05-22-31