WIND Brochure
6Pages

{{requestButtons}}

Catalog excerpts

WIND Brochure - 1

Ordering Information Communications With an embedded web server, WebMaster® WIND utilizes standard TCP/IP Internet communications. Remote communications can be established with WebMaster® WIND via the Internet or on a direct line with modem-to-modem capability. USB Plug and Play and Ethernet are included to allow easy on-site access for plant personnel and system operators. Multiple users can access the controller simultaneously. A graduated password protection system allows users varied degrees of access from view only to full system configuration. In addition, WIND delivers a range of user-friendly information reporting tools including email notifications for datalogs, alarms and system summaries. Industrial Water Treatment Controllers WebMasterONE is the most advanced online cooling tower and boiler controller in the water treatment industry. The flexible multi-I/O platform allows you to control multiple cooling towers, boilers, closed loops, and condensate lines with just one controller. An extensive assortment of integrated communications and data handling features are included that enable water treatment professionals to provide more effective water management services to their customers. Walchem has made use of the Internet as a remote access communications platform for industrial control equipment a practical reality.  While others just attempt to reduce the cost of embedded web server hardware,  Walchem has solved the problem of the high cost and lack of availability of a permanent connection to the Internet.  1 SENSOR INPUTS REQUIRED 1 = One sensor input 3 = Three sensor inputs 2 = Two sensor inputs 4 = Four sensor inputs WebMaster® WIND makes programming your process simple and fast and does not require any proprietary software to reside on your computer. Set-up and programming are all done via a standard web browser. 2 VOLTAGE CODE 0 = Prewired w/USA power cord, 0 powered relays, 8 dry contact relays 1 = Prewired w/USA cords, 7 powered relays, 1 dry contact relay 2 = Prewired w/USA cords, 8 powered relays 3 = Prewired w/USA cords, 4 powered relays, 4 dry contact relays 4 = Hardwired, 0 powered relays, 8 dry contact relays 5 = Hardwired, 8 powered relays 6 = Hardwired, 7 powered relays, 1 dry contact relay 7 = Hardwired, 4 powered relays, 4 dry contact relays E = Prewired w/ USA power cord, 4 powered relays, 4 opto-isolated (pulse) relays F = Prewired w/ USA cords, 4 dry contact relays, 4 opto-isolated (pulse) relays G = Hardwired, 4 powered relays, 4 opto-isolated (pulse) relays H = Hardwired, 4 dry contact relays, 4 opto-isolated (pulse) relays Easy to follow menus and system set-up screens make programming user friendly and intuitive. Once WebMaster® WIND is installed, the Start-up menu jump-starts you through the top level set-up. The Input, Output and Utility menus guide you through the rest of the programming. • USB Plug and Play: For local monitoring and reconfiguration of your WebMaster® WIND via LapTop or dedicated on-site PC. • ShoulderTap® Internet Communications: For monitoring and reconfiguration of your WebMaster® WIND remotely via the Internet (requires landline modem card option). • DirectTap Modem-to-Modem: For remote monitoring and reconfiguration of your WebMaster® WIND using traditional modem-to-modem communications (requires landline modem card option). Phone Company • Ethernet: For monitoring and reconfiguration of your WebMaster® WIND via Local Area Network or remotely via the Internet. Modbus TCP/IP is available to seamlessly connect to building energy & process manageInternet ment, distributed control, and SCADA systems Cell Service provider • Cellular: For monitoring and reconfiguration of your WebMaster 3 ANALOG OUTPUTS N = No electrode 1 = One 4-20 mA output board 2 = Two 4-20 mA output boards 3 = Three 4-20 mA output boards 4 = Four 4-20 mA output boards ETHERNET NETWORKING 4 INPUT OPTIONS N = None A = Analog Input board (8 inputs) D = Digital Input board (6 inputs) B = Both Analog and Digital Input boards Walchem’s Ethernet Networking allows you to leverage the power of the WebMaster® WIND communications abilities. By using the Local Area Network (LAN) or by connecting the WebMasters together via Ethernet, you can access all the controllers on the network from a single phone line. By utilizing the existing LAN, wiring can be minimized. The controller simply plugs into the nearest LAN connection via a standard Ethernet cable. The Master controller detects the other Walchem devices on the network and provides a single point of access. 5 DIGITAL COMMS HARDWARE (USB & ETHERNET STANDARD) N = No additional communications M = Modem landline card G = Cellular Modem card (GPRS) WIND remotely via the Internet (requires cell modem and VTouch option). 6 DIGITAL COMMS SOFTWARE N = No additional communications 1 = Ethernet networking (Master capability) 2 = Modbus TCP 3 = Ethernet networking (Master capability + Modbus TCP) WebMaster Slave Units WebMaster Master Unit WebAlert® Slave Unit WebMaster® WIND WebMaster® WIND sets a new standard for Industrial Water Treatment Controllers. The WIND has a flexible multi-input/output platform, a wide range of analytical sensor measurement capabilities, and an extensive assortment of integrated communications and data handling features. Beyond the extensive list of capabilities, WIND has set an industry-wide ease-of-use benchmark. All together, it represents the perfect balance between Innovation, Flexibility, and Simplicity. Metering Pumps The E-Class is the most innovative and comprehensive metering pump product line in the world. Over 50 years of pump experience and a commitment to superior mechanical design has led to development of many industry firsts, including 360 stroke-per-minute technology, IP67 waterproof construction, and the world’s highest capacity solenoid metering pumps. WebAlert® Remote Monitor Fully integrates functions of a transmitter, PLC, datalogger and auto-dialer into a rugged, industrial, NEMA 4X package Walchem’s WebAlert is the first stand alone remote monitoring device that can web enable your installed equipment without having to replace or upgrade it. No proprietary software required to view live data - just a web browser Access live or stored data remotely within the facility (LAN connection) or from anywhere in the world (cell or landline modem) No expensive PLC programming and re-programming – all changes made intuitively using a standard web browser VTouch® provides quick, centralized 24/7 awareness of account status with the ability to LIVE Connect to any of your controllers in the field with one simple mouse-click. AGENCY CERTIFICATIONS Safety ANSI/UL 61010-1:2012 3rd Ed. C22.2 No. 61010-1:2012 3rd Ed. IEC 61010-1:2010 3rd Ed. EN 61010-1:2010 3rd Ed. EMC IEC 61326-1:2005 EN 61326-1:2006 Note: For EN61000-4-6,-3 the controller met performance criteria B. *Class A equipment: Equipment suitable for use in establishments other than domestic, and those directly connected to a low voltage (100-240 VAC) power supply network which supplies buildings used for domestic purposes. Extensive built-in Plug & Play communications options: • Ethernet • USB (Laptop and FlashDisk support) • Landline modem • Cell modem A wide range of direct sensor measurements: • pH • ORP • Chlorine Dioxide • Ozone • Conductivity • Peracetic Acid • Free Chlorine • Electrodeless Conductivity PID control for relay and analog outputs Instant alarm notification via cell phone text message, email, or local alarm relay Walchem integrates its advanced sensing, instrumentation, fluid pumping and communications technologies to deliver reliable and innovative solutions to the global water treatment market. Our in-house engineering is driven by quality, technology and innovation. For more information on the entire Walchem product line, visit: www.walchem.com. Walchem, Iwaki America Inc. Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA Phone: 508-429-1110 www.walchem.com System status reports and datalog files can be emailed automatically Water Treatment Wastewater Treatment

Open the catalog to page 1

All Walchem catalogs and technical brochures

  1. ADV series

    2 Pages

  2. WPH/WDP

    4 Pages

  3. WECT/WEDT

    4 Pages

  4. WCT/WDT

    4 Pages

  5. EJ

    2 Pages

  6. W100P

    4 Pages

  7. W600

    4 Pages

  8. HRP Series

    2 Pages

  9. WCU/WNI410

    4 Pages

  10. WDIS410

    4 Pages

  11. Paddlewheel

    2 Pages

  12. Level Sensor

    2 Pages