Wachendorff Encoder WDGI 115M - 18 Pages

Add to MyDirectIndustry favorites
Wachendorff Encoder WDGI 115M

Catalog excerpts

Wachendorff Automation ... systems and encoders • Complete systems • Industrial rugged encoders to suit your application • Standard range and customer versions • Maximum permissible loads • 48-hour express production • Made in Germany • Worldwide distributor network WDGI 115M Errors and modifications reserved. © Wachendorff Automation GmbH & Co. KG 2015-05-05 -1-

 Open the catalog to page 1

Encoder WDGI 115 M • Digital Tachogenerator” with robust tacho flange • Housing cap die cast aluminium, with particularly eco-friendly powder coating • Up to 25000 PPR by use of high grad electronics • High noise immunity against frequency inverters • Protection to IP67, shaft sealed to IP65 • 11 mm shaft • Full connection protection with 10 VDC up to 30 VDC • High output frequency 600 kHz/2 MHz • Optional: -40 °C up to +85 °C, Protection to IP67 all around, Pressure equalising membrane www.wachendorff-automation.com/wdgi115m Resolution Max. pulses per revolution PPR Mechanical Data Housing...

 Open the catalog to page 2

WDGI 115M: Cable connection K2, L2, axial, with 2 m cable axial, shield not connected axial, shield connected to encoder housing Assignments Circuit GND (+) Vcc A B N Light reserve warning A inv. B inv. N inv. Shield WDGI 115M Errors and modifications reserved. © Wachendorff Automation GmbH & Co. KG 2015-05-05 -3-

 Open the catalog to page 3

WDGI 115M: Cable connection K3, L3, radial, with 2 m cable radial, shield not connected radial, shield connected to encoder housing Assignments Circuit GND (+) Vcc A B N Light reserve warning A inv. B inv. N inv. Shield WDGI 115M Errors and modifications reserved. © Wachendorff Automation GmbH & Co. KG 2015-05-05 -4-

 Open the catalog to page 4

axial, 5-pin, Connector connected to encoder housing axial, 6-pin, Connector connected to encoder housing axial, 8-pin, Connector connected to encoder housing axial, 12-pin, Connector connected to encoder housing GND (+) Vcc A B N Light reserve warning A inv. B inv. N inv. n. c. WDGI 115M Errors and modifications reserved. © Wachendorff Automation GmbH & Co. KG 2015-05-05 -5-

 Open the catalog to page 5

radial, 5-pin, Connector connected to encoder housing radial, 6-pin, Connector connected to encoder housing radial, 8-pin, Connector connected to encoder housing SH12 radial, 12-pin, Connector connected to encoder housing Assignments SH5 5-pin GND (+) Vcc A B N Light reserve warning A inv. B inv. N inv. n. c. WDGI 115M Errors and modifications reserved. © Wachendorff Automation GmbH & Co. KG 2015-05-05 -6-

 Open the catalog to page 6

axial, 7-pin, Connector connected to encoder housing GND (+) Vcc A B N Light reserve warning A inv. B inv. N inv. n. c. Shield WDGI 115M Errors and modifications reserved. © Wachendorff Automation GmbH & Co. KG 2015-05-05 -7-

 Open the catalog to page 7

radial, 7-pin, Connector connected to encoder housing GND (+) Vcc A B N Light reserve warning A inv. B inv. N inv. n. c. Shield WDGI 115M Errors and modifications reserved. © Wachendorff Automation GmbH & Co. KG 2015-05-05 -8-

 Open the catalog to page 8

axial, 12-pin, Connector connected to encoder housing GND (+) Vcc A B N Light reserve warning A inv. B inv. N inv. n. c. Shield WDGI 115M Errors and modifications reserved. © Wachendorff Automation GmbH & Co. KG 2015-05-05 -9-

 Open the catalog to page 9

radial, 12-pin, Connector connected to encoder housing GND (+) Vcc A B N Light reserve warning A inv. B inv. N inv. n. c. Shield WDGI 115M Errors and modifications reserved. © Wachendorff Automation GmbH & Co. KG 2015-05-05 -10-

 Open the catalog to page 10

axial, 12-pin, Connector connected to encoder housing GND (+) Vcc A B N Light reserve warning A inv. B inv. N inv. n. c. Shield WDGI 115M Errors and modifications reserved. © Wachendorff Automation GmbH & Co. KG 2015-05-05 -11-

 Open the catalog to page 11

radial, 12-pin, Connector connected to encoder housing GND (+) Vcc A B N Light reserve warning A inv. B inv. N inv. n. c. Shield WDGI 115M Errors and modifications reserved. © Wachendorff Automation GmbH & Co. KG 2015-05-05 -12-

 Open the catalog to page 12

axial, 4-pin, Connector connected to encoder housing axial, 5-pin, Connector connected to encoder housing axial, 8-pin, Connector connected to encoder housing SB12 axial, 12-pin, Connector connected to encoder housing Assignments SB4 4-pin GND (+) Vcc A B N Light reserve warning A inv. B inv. N inv. n. c. Shield WDGI 115M Errors and modifications reserved. © Wachendorff Automation GmbH & Co. KG 2015-05-05 -13-

 Open the catalog to page 13

radial, 4-pin, Connector connected to encoder housing radial, 5-pin, Connector connected to encoder housing radial, 8-pin, Connector connected to encoder housing SC12 radial, 12-pin, Connector connected to encoder housing Assignments SC4 4-pin GND (+) Vcc A B N Light reserve warning A inv. B inv. N inv. n. c. Shield WDGI 115M Errors and modifications reserved. © Wachendorff Automation GmbH & Co. KG 2015-05-05 -14-

 Open the catalog to page 14

The encoder WDGI 115M with the output circuit types F24, G24, H24, I24, P24, R24, F05, ACA G05, H05, I05, P05, R05, 245, 524, 645 is also available with the extended temperature range -40 °C up to +85 °C [-40 °F up to +185 °F] (measured at the flange). Cable length The encoder WDGI 115M can be supplied with more than 2 m cable. The maximum cable XXX = Decimeter length depends on the supply voltage and the frequency; see www.wachendorffautomation.com/atd Please extend the standard order code with a three figure number, specifying the cable length in decimetres. Example: 5 m cable = 050 IP67...

 Open the catalog to page 15

Example Order No. Type WDGI 115M Your encoder Output circuit HTL HTL inverted TTL TTL TTL, RS422 comp., inverted TTL, RS422 comp., inverted HTL HTL HTL inverted HTL inverted TTL, RS422 comp., inverted TTL, RS422 comp., inverted TTL TTL, RS422 comp., inverted HTL HTL inverted TTL, RS422 comp., inverted 1 Vpp sin/cos Light reserve warning • • • • • - WDGI 115M Errors and modifications reserved. © Wachendorff Automation GmbH & Co. KG 2015-05-05 -16-

 Open the catalog to page 16

Electrical connections Description Cable: length (2 m standard, WDG 58T: 1 m) axial, shield not connected axial, shield connected to encoder housing radial, shield not connected radial, shield connected to encoder housing Connector: (shield connected to encoder housing) connector, M16x0.75, 5-pin, axial connector, M16x0.75, 5-pin, radial connector, M16x0.75, 6-pin, axial connector, M16x0.75, 6-pin, radial connector, M16x0.75, 8-pin, axial connector, M16x0.75, 8-pin, radial connector, M16x0.75, 12-pin, axial connector, M16x0.75, 12-pin, radial connector, M16x0.75, 7-pin, axial connector,...

 Open the catalog to page 17

All Wachendorff Automation GmbH & Co. KG catalogs and technical brochures

  1. EtherCAT

    2 Pages

  2. PROFINET

    2 Pages

  3. PROFIBUS

    2 Pages

  4. WDG(I) encoders

    2 Pages

  5. WDG 58T

    5 Pages

  6. WDG 53V

    7 Pages

  7. WDG 50B

    9 Pages

  8. WDG 40K

    11 Pages

  9. WDG743XIOM

    43 Pages

  10. Encoder WDG 30A

    7 Pages

  11. WDG 67Q

    14 Pages

  12. WDGI 58N

    18 Pages

  13. WDG 40A

    11 Pages

  14. WDG 40S

    11 Pages

  15. WDG 70B

    14 Pages

  16. WDG 63Q

    14 Pages

  17. WDG 63B

    14 Pages

  18. WDG 58K

    14 Pages

  19. WDG 58H

    13 Pages

  20. WDG 58D

    14 Pages

  21. WDG 58C

    14 Pages

  22. WDG 115M

    14 Pages

  23. WDG 58E

    13 Pages

  24. WDG 58B

    14 Pages

  25. WDG 58A

    14 Pages

  26. Encoder WDGI 58K

    18 Pages

Archived catalogs