Preliminary
SCL1700 Series
Inclinometer Subassembly
features
■ Available range: ±100
■ DC...3 Hz sensing bandwidth (controlled frequency response)
■ Easy to use and design in
■ 0.0010 resolution analogue output
■ 0.20 accuracy
■ Dual axis inclination measurement
■ Advancedfailuredetection
benefits
■ Excellent long term stability
■ Sensing element filtered high frequency vibration
■ Outstandingshockdurability
applications
■ Platform tilt measurement
■ Equipment and instrument condition monitoring
■ Inclination based position measurement
For customized product please contact VTI Technologies
electrical characteristics
Parameter
Condition
Min
Typ.
Max
Units
Supply voltage "
7
15
28
V
Current consumption
4.5
mA
Output load
Resistive
T.B.D
kOhm
Capacitive
T.B.D.
nF
Operating temperature
-40
85
°C
Mechanical shock
1 mdroponconcrete
20 000
g
performance characteristics
Motel. Mote2. Mote 3. Mote 4.
Mote 5.
The measuring range is limited by sensitivity, offset and supply voltage rails ofthe device. Note 7.
Offset specified as Voffset = Vout(@0 °) [V].
+15 V supply voltage used in calibration and testing.
Offset calibration errorspecified as Offset_Calib_error = arcsin(Offset_Calib_error_in_g)[°], Note 8.
Offset_Calib_error_in_g = {Vout(@0 °) - 2.5 V} / Vsens [g], Vsens=11.46 V/g.
Offset temperature error specified as Note 9.
Offset_Error_@_temp. = arcsin(Offset_Error_@_temp_in_g) [0 ],
Offset_Error_@_tempJn_g = {Vout ® temp. - Vout ® room temp.} / Vsens [g], Vsens=11.46 V/g.
Sensitivity target in calibration Vsens _nom11.46 V/g (-> 200 mV/°)
Sensitivity specified as Vsens = {Vout(®+10 °) - Vout(@+lo °)}/(2*sin(10 °) g) [V/g].
Sensitivity calibration error specified as
Sensitivity_calibr_error = {Vsens - Vsens_nom} / Vsens_nom x100 % [%], Vsens_nom = nominal sensitivity. Sensitivity temperature errorspecified as
Sensitivity_temp_error = {Vsens @temp- Vsens ® room temp} / Vsens ® room temp} x 100 % [%]. rrom best fit sine-function to output through -100 and +10 °.
Mote 6.
VTI^
TECHNOLOGIES
Rev. 10 Sept 2004
VTI Technologies reserves the right to modify this specification without prior to notice.