| | | SCA121T Series | | |
| | | |
| | | Stand Alone Inclinometer | | |
| | | |
| | | Dual Axis Analog Output | | |
| | | |
| | | FEATURES 0,1 ° accuracy Resolution < 0,001 ° Operating temperature range -40...+85 °C Long term stability < 0,02 ° Shock resistance >20 000 g Sensing element -3 dB @ 18 Hz Main dimensions: 30x30x13 mm size, single or dual axis Voltage output RoHS compatible | | BENEFITS Excellent long term stability Sensing element controlled frequency response Outstanding shock durability Harsh environment robustness APPLICATIONS Platform tilt measurement Equipment and instrument condition monitoring Inclination based position measurement Rotational orientation measurement | | |
| | | |
| | | |
| | | For customised product please contact VTI Technologies | | |
| | | |
| | | ELECTRICAL CHARACTERISTICS | | |
| | | |
| | | | | | | | | | | | | | | Parameter | Condition | Min. | Typ | Max. | Units | | | | | Supply voltage | Unregulated or | 7 | 16 | 35 | V | Applies to: -D03, -D07 | | | | regulated ratiometric | 4.75 | 5 | 5.25 | V | Applies to: -D05 | | | | Current consumption | | | 5 | | mA | | | | | Output load | Resistive | 10 | | | kil | | | | | | Capacitive | | | 20 | nF | | | | | | | | | | | | | | | |
| | | |
| | | | | | | | | | | | | | PERFORMANCE | CHARACTERISTICS | | | | | | | Parameter | Condition | SCA121T-D03 | SCA121T-D07 | SCA121T-D05 | Units | | | | Measuring range (1 | | ±90 | ±30 | ±90 | 0 | | | | Supply voltage | | 7 ...35 | 7 ...35 | 5 ±0.25 | V | | | | Measuring axis | (see "Directions") | X-Y | X-Y | X-Y | | | | | Offset (2, 5 | Output at 0 ° | 2.5 | 2.5 | 2.5 | V | | | | Offset zero point error (5 | Max. deviation | 1 | 1 | 1 | 0 | | | | Offset temperature error | 0...70 °C -25...85 °C | ±0.2 ±0.6 | ± 0.2 ±0.6 | ± 0.2 ±0.6 | 0 0 | | | | Sensitivity | | 2 | 4 | 2 | V/g | | | | | | 35 | 70 | 35 | mV/o(@offset pos.) | | | | Sensitivity temperature error (5 | 0.70 °C -25...85 °C | -0.8...0.3 -1.5 ...0.5 | -0.8...0.3 -1.5...0.5 | -0.8 ...0.3 -1.5...0.5 | % % | | | | Nonlinearity | Sinus output | N/A | 0.1 | N/A | 0 | | | | Frequency response -3 dB (3 | | 18 | 18 | 18 | Hz | | | | Cross-axis sensitivity (4 | | 3 | 3 | 3 | % | | | | | | | | | | | | | |
| | | |
| | | Typical values unless otherwise specified. | | |
| | | |
| | | Note 1 The measuring range is limited by the sensitivity and offset. Note 4 The cross-axis sensitivity determines how much inclination, perpendicular to the measuring Note 2 Offset specified as Output @ 0 °. axis, couples to the output. Note 3 The frequency response is determined by the sensing element's internal gas damping. Note 5 For optimum zero point accuracy, mounting angle of the part can be adjusted. The output has true DC (0 Hz) response. | |
| | | |
| | | MEASURING DIRECTIONS | | |
| | | |
| | | X-axis Y-axis | | |
| | | |
| | | Mounting position 1 (Horizontal) | | |
| | | |
| | | Mounting position 2 (Vertical) | | |
| | | |
| | | Devi ation Negative ind, Zero posi tion, Posi tivei ncl. Devi ati on Posi tive ind, Zero positi on, Negative i ncl. Figure 1. Positions Notes: It is important that the part is parallel to the mounting plane, and that the output equals the zero value when sensor is in zero position. Zero position: Please note the picture above which provides information on how the output of the accelerometer behaves in different circumstances when assembled. Please also note that you can rotate the part around the measuring plane for optimum mounting location. | | |
| | | |
| | | ₯11^ TECHNOLOGIES | | |
| | | Rev. 5 / 3 Dec 2008 | | |
| | | VTI Technologies reserves the right to modify this specification without prior to notice. | | |
| | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |