Working System / Options
All front door opening- and chest cabinets can be furnished with the following working systems,
provided there are no limitations to space, design or material properties Working system CON CH
High Humidity
ISO 6270-2 CH
(DIN 50017 KK) Working system CON AIR
Aeration “AIR”
ISO 6270-2, ISO 6988
DIN 50014, (DIN 50018) Working system CON ADO Automat. Door opening “ADO” ISO 6270-2
DIN 50014 (DIN 50017)
Demineralised water is warmed up Ambient air (18°C-28°C /40-
60%rel. humidity) are blown into When the preselected test time of
the high humidity phase elapsed
the front door is opened automati-
cally thus the specimen are dried
by ambient air.Options: to usually 40°C and evaporated inthe upper space of the
testing chamber.
Options:
CTD system "regulated condensa-
tion"
Increased working temperature -
to 60°C, or 70 °C the testing chamber by means of a built-in fan and distributed evenly by a distribution pipe thus there is an even drying of the specimen
Options:
CTD System “Regulated Condensation” “Regulated Condensation” Increased working temperature- bis 60°C, or 70 °C
5 % Sodium chloride solution or amodified test solution is sprayed
into the testing chamber by com-
pressed air to form a fine mist at
35°C (SS)or 50°C (CASS).
Options: Increased working temperature
- bis 60°C, or 70 °C
Automatic water refill >
Working system SAL
Salt spray
ISO 9227
DIN 50021 SS, ESS, CASS Working system WL
Forced Air drying
Corporate standards Working system A-KES
Automatic SO2 Dosing”
ISO 6988
(DIN 50018)
Ambient air is heated up and intro-
duced into the test chamber by a
built-in fan. An air guiding pipe
provides an uniform flow through
the chamber thus there is an even
drying of the specimen.
Options:
Rotating speed variable fan For conducting tests using pollu-
tion gases such as SO2, the gas is
introduced into the chamber from
the storage bottles, metered by a
calibrated
mass flow meter.
Kesternichtests can be carried out
day by day without any manually
operation.
The humid atmosphere is formedby
spraying of water in the testing
chamber. The humidity is meas-
ured by a capacity sensor and con-
trolled by a microprocessor
controller “Prohesion Test (PR)” for intermit- tent working mode.
Automatic switch on to the second
test solution tank.
CON CH -System for constant high
humidity tests
Cleaning of the testing chamber,
Cleaning of the tubing system >
Working system RF
Controlled Humidity I
Corporate Standards,
DIN 4570 Working system ARF
Controlled Humidity I
Corporate Standards Working system
Alternating Dipping “WTP”
Corporate Standards
The humid atmosphere is formed
by spraying of water in the testing
chamber. Additionally a
industrial steam generator supplies steam to
achieve major relative humidity
values. The
humidity sensor is
mounted outside the testing cham-
ber to prevent from contamination
for instance by salt spray. During
the humidity testing phase the Specimen can be dipped into rea-
gent solutions during specified
duration and exposed to humid
atmospheres inside the testing
chamber. sensor is pushed into the chamber. Due to the high sensitivity of the
sensor the humidity can be con-
trolled by the PLC with a high ac-
curacy. >
These descriptions are subject to technical adjustments or improvements