Catalogue Advanced Corrosion test equipment
www.vlmgmbh.de
print switch display
Page / 12
Where to buy
this product ?
Request
a Quote
VLM - 151609, 68421, 16074, 2322, 208910, 83578, 254616
/ 12
See other catalogues for VLM
Text version of the page

Unique: The patented CTD-System for controlled water condensation

This difference of the temperature between the waterbath and sample zone, crucial for the condensation of the water, is regulated. The CTD-Models equipped with this system and held constantly on a preselected desired value, e.g. 39°C. If this is exceeded, the fans built in the rear part of the outside roof suck ambient air through the sapce be- tween internal and outside roof. So the heat derives from the testing chamber. In addition these conditions optimal for the condensation test are reached by the even heating up of the water by means of the entire floor area.The CTD system offers not only crucial advantages forcondensation testing cabinets but also for cyclic corrosion test as well as for combined salt spray/high humidity test- ing cabinets. This option is available both for front door opening cabinets as well as for chest devices.

Salt spray modeCondensation mode

Fast Heating Up and Cooling Down Rates

Compact Case Design Industrial safes space

The good heat transfer of the stainless steel floor allows fast heating rates. Contrary to testing chambers made of GRP fast temperature changes do not damage our devices. If required the cooling can forced by rinsing water over the walls. In preparation: Ramp functions, in order to make special testing methods possible with temperature/humidity ramps. Likewise the slower-acting behaviour of other de- vices - e.g. for comparison tests - can be simulated. A good example of the service friendliness represents the com- pressed air industrial humidifier. The filterele- ment can be exchanged from the user himself. The humidifier must not be removed. In addition the humidifier from thermal shock resist- ant glass serves as hot water reser- In the comparison for this a common 400L GRP chest needs 2.00 x 0.89 m.Moreover due to the separation of thetesting cabinet and the foot standing cabi- net there are no problems with the trans- voir, if e.g. shortcyclic corrosions tests require preheated water. This picture shows what we understandunder “Compact Design”. A complete plant with a 400 L testing chamber for instance for combined salt spray and high humidity or even full automatic cyclic cor- rosion tests requires a floor area of only 1.25 x 0.70 m. portation even if there is narrow access to the laboratory. And if there is no floor The test solution is sucked by aperistaltic and distributed to the area the SAL/CON or CCT-cabinet fits on a conventional laboratory table. spray nozzle manufacturer. The flow is perma-nently indicated by a corrosion re- sistant flowmeter. Due to the independence of the test solution flow from the air pressure the drop- let size of the fog can be influenced.

...there are more good reasons to decide in favour of a VLM Corrosion Test Cabinet.

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
pdf-page pdf di En 2008-12-49-03