Group: IDEX Corporation
Catalog excerpts
NEW Viking ® Electrically Heated Pumps Electric heat, now available on Viking Universal Seal series cast iron pumps, can be used as an alternative to heating with hot oil or steam. ■ Lower installation costs in remote locations when steam or hot oil is not available or requires long piping runs. ■ Reduced environmental costs by eliminating hot oil leaks. ■ Reduced energy costs with heat source in pump vs. external heat tracing. ■ Simplified service by eliminating hot oil or steam pipe connections. ■ Improve safety by eliminating hot oil or steam leaks. Capacity to 155 M³/Hr (685 GPM) Pressure to 14 Bar (200 PSI) Viscosity 0.1 to 440,000 cSt (28 to 2,000,000 SSU) Temperature to +232°C (+450°F)
Open the catalog to page 1Viking Temperature Control System To melt solid material in the pump prior to startup, Viking pumps are available with traditional jacketing to circulate steam or hot oil, or with built-in electric heat cartridges. Electric heat cartridges offer a number of advantages over steam, heat transfer oils or electric heat tracing, including: Viking’s electrically heated pumps include the heat cartridges and a ½” NPT port for a temperature sensor. Temperature control can be accomplished using your plantstandard controllers, or using Viking’s temperature control system. The Viking system includes a...
Open the catalog to page 2Pump is heated by electric heat cartridges vs. heating jackets ■ Patented design uses heat cartridges installed in the head to quickly melt asphalt throughout the casing. ■ Heat cartridges located on bracket or casing heat area behind the rotor, to ensure sufficient heating in the shaft bushing and stuffing box. Head Cartridges Bracket/Casing Cartridges Performance Port Size ① Nominal Rating Pump Size Head Cartridges Watts / Cartridge (Head) Bracket / Casing Cartridges ④ Watts / Cartridge (Bracket or Casing) ④ Total Watts Note: Maximum temperature for standard pump 450°F / 232°C. Higher...
Open the catalog to page 3Thermocouple (included with control system) Diagram 1 Power Source Type J thermocouple with thermowell in weather-resistant housing with ½” MNPT fitting to mount in pump. Controller (included with control system) Enclosure: 1/16 DIN, NEMA 4X / IP66 for panel mount Fuse Mains power: 240 VAC, 1 phase, 50/60 Hz SEE TABLE ON PAGE 3 FOR TOTAL WATTAGE AND NUMBER OF HEATERS Heater Output: 15A NO-ARC, Form A Control Algorithm: PID with preset bandwidths READY LIGHT Heat Cartridges "Setpoint Achieved" Relay Output: Mechanical relay, 5A, Form A Agency Approvals: UL, CSA, CE, RoHS, W.E.E.E., FM NOTES:...
Open the catalog to page 4All Viking Pump catalogs and technical brochures
-
OEM Custom Solutions
6 Pages
-
LVP Vane Pumps
8 Pages
-
Viking-Built Double Pumps
8 Pages
-
Dual Containment
1 Pages
-
855 Mag Drive Pumps
8 Pages
-
XPD Brochure
7 Pages
-
Motorspeed 2016 Infographic
2 Pages
-
Hygienic Series Poster
1 Pages
-
Hygienic Series
5 Pages
-
Viking Master Catalog Combined
560 Pages
-
4076, 4176
8 Pages
-
HEAVY DUTY PUMPS, SERIES 4195
11 Pages
-
Metric Motor Speed
6 Pages
-
Universal Mag Drive
10 Pages
-
Universal Seal Pumps
16 Pages
-
Viking Product Catalog
56 Pages
Archived catalogs
-
Composite Mag Drive
8 Pages
-
Gear Reducers
8 Pages
-
Power Load Monitors
2 Pages
-
SG External Gear Pumps
16 Pages
-
Lid-Ease® Basket Strainers
2 Pages
-
Universal Seal Pumps
16 Pages
-
Viking pump - Product Flyers
20 Pages