Data Logger VPA-0270
MESSELEKTRONIK
functional description
The data logger VPA-0270 serves for the monitoring and event storage in four channels with the following features:
• one DMS-strap input
• two Pt-100-inputs
• one frequency input for NPN or PNP signals
• battery backed alarm memory for maximal 50.000 stored events
• battery backed real time clock
• serial interface for PC-communication
• event monitoring in second cycle
The function of the data logger covers the permanent storage of the four channels in second time. Acomparison of the current measurements is permanently carried out with switching thresholds (alarm thresholds) defined before. A transgression or underrun of the thresholds is understood as an event to record in writing and is stored with the date and time.
The data logger with connecting elements, all functional moduls and the data memory is on the circuit board witch can be put into an open hat rail case approx. 110 mm x 110 mm. It is conceived for the installation into a control cubicle and can be puton on a hat rail.
The configuration of the data logger as well as the access to the stored event data is carried out with a PC-programme.
technical data
operating voltage event memory internal non interface frequency input case
size of the circuit board other
24 V DC ±20 %
256 KB; battery backed
12 bit resolution
RS232
0 - 3 kHz
hat rail case, open
108 mm x 107 mm
battery backed real time two control-LED's
jumper for internal command transfer
2007-04-03
leaving technical changes and errors
VPA-0270_e.cdr
VELOMAT Messelektronik GmbH . Schwarzer Weg 23b . D-01917 Kamer
Telefon (03578) 3749-0 . Telefax (03578)

pageCatalog pdf di En 2012-06-22-01