VEGAFLEX 63
WA
Approval
XX without .............................................................
CX ATEX II 1G, 1/2G, 2G EEx ia IIC T6 .............
CA ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + WHG
DX ATEX II 1/2G, 2G Ex d ia IIC T6 1> .............................................
Version / Temperature
B Cable 04mm PFA insul. w. gravity weight / -40...150°C
E Rod 010 mm PFA insulated / -40...150°C ......................
Process fitting / Material
FC Flange DN50PN40, DIN2501 / PTFE-plated ........
FD Flange DN80PN40, DIN2501 / PTFE-plated ........
FE Flange DN100PN16, DIN2501 / PTFE-plated ......
KC Flange DN50PN40 EN1092-1 / PTFE-plated .......
KD Flange DN80PN40 EN1092-1 / PTFE-plated .......
KE Flange DN100PN16 EN1092-1 / PTFE-plated .....
AE Flange 2" 150lb RF, ANSI B16.5 / PTFE-plated ....
AI Flange 3" 150lb RF, ANSI B16.5 / PTFE-plated ....
AK Flange 4" 150lb RF, ANSI B16.5 / PTFE-plated ....
CA Tri-Clamp 2" PN16 / PTFE-TFM 1600 ....................
CE Tri-Clamp 3" PN10 / PTFE-TFM 1600 ....................
CC Tri-Clamp 4" PN6 / PTFE-TFM 1600 .......................
RA Bolting DN40PN40 DIN11851 / PTFE-TFM 1600 RB Bolting DN50PN25 DIN11851 / PTFE-TFM 1600
Electronics
H Two-wire 4...20mA/HART® ............................................
V Four-wire 4...20mA/HART® 1> .........................................
P Profibus PA .......................................................................
F Foundation Fieldbus ......................................................
Housing / Protection
K Plastic / IP66/IP67 .....................................................
A Aluminium / IP66/IP68 (0.2 bar) ..............................
D Aluminium double chamber / IP66/IP68 (0.2 bar)
8 StSt (electropolished) 316L / IP66/IP68 (0.2bar) . Cable entry / Cable gland / Plug connection
M M20x1.5 / with / without ......................................
N 1/NPT / without / without ....................................
Indicating/adjustment module (PLICSCOM)
X Without ...........................................................
A Top mounted ................................................
I Additional equipment X without .....................................................
1) Only in conjunction with Housing / Protection "D"
Length in mm (from seal surface)
Cable 04 mm/PFA insulated (1000-32000 mm) per 100 mm Rod 010 mm/PFA insulated (300-4000 mm) per 100 mm
• Further process fittings and options on request
Level measurement - Guided microwave