Downward-Looking SUMO Source for Gallium and Indium - 1

Downward-Looking SUMO Source for Gallium and Indium Schematic of source with downward-looking crucible. • Patented design with more than 75 in the field • Accommodates molten charge materials in downward-looking ports • Substantially increases capacity of shallow upward ports • Excellent flux stability and uniformity • PBN crucible construction optimizes material quality Description The Veeco Downward-Looking SUMO® Source is a dual filament source with an asymmetric SUMO crucible, uniquely designed to accommodate a molten charge in a downward-facing source port. The narrow orifice is offset to contain the melt, while a tapered exit cone provides excellent flux uniformity. This novel crucible shape is available only with Veeco’s patented SUMO technology. Hot-lip heating in the exit cone region prevents charge recondensation and minimizes Group III-related oval defects. This design and position of the base heater filament is tailored to the non-uniform distribution of charge material in the crucible for optimal flux stability. This source is not for use with aluminum. Performance and Benefits Downward-looking source ports enable users to expand the total number of Group III sources available on an MBE system with downward looking source ports. Redundant sources increase the total charge capacity for the most commonly used materials, and allow for rapid switching between different flux settings by using separate sources for each desired flux. The Downward-Looking SUMO Source also offers increased charge capacity for molten source materials in shallow upward-facing ports. For example, a 175g Downward-Looking SUMO Source in the shallow upward-looking port on a GEN III™ System has a capacity of 425g of gallium while a standard 400g SUMO would have a capacity of 49g in the same port. The exit cone design assures flux uniformities comparable to those achieved with a system’s original Group III sources. Standard 1% uniformity has been demonstrated across a 2” wafer in a MOD GEN II™ System.

Open the catalog to page 1
Downward-Looking SUMO Source for Gallium and Indium - 2

Product Specifications Source Characteristics Crucible Type Crucible Material PBN typical. Contact Veeco to inquire about other available materials Filament Type Dual Ta wire heater filaments, independently controllable Minimum Mounting Flange Size Thermocouple Type Two Type C (W/Re 5/26%) flag thermocouples In-Vacuum Length Standard 2.15”/55mm With Water-Cooling 2.7”/69mm Typical Operating Temperature Maximum Outgassing Temperature 1600°C (using both filaments) Optional cooling coil Power Supplies Two power supply/temperature controller units are suggested. The Veeco Auto-Ranging DC Power...

Open the catalog to page 2

All VEECO catalogs and technical brochures

  1. Quest OMS

    2 Pages

  2. SPECTOR-HT

    2 Pages

  3. GENxplor™

    2 Pages

  4. K465i

    2 Pages