Catalogue Scientific Instruments and Consumables
www.varianinc.com
print switch display
Page / 476
Contact the
Manufacturer
Where to buy
this product ?
Request
a Quote
Varian - 94979
/ 476
See all the products Varian
Text version of the page
Bond Elut Cartridge SPE
Bond Elut® Cellulose
Bond Elut® CBA
• Base silica: 40 urn or 120 urn irregularly-shaped, acid-washed silica, 60 A mean pore size
• Bonded functional group: carboxylic acid
• Sorbent pKa: 4.8
• Mean capacity: 0.35 meq/g
• Endcapped:yes
• Typical percent carbon loading: 7.4%
• Primary retention mechanism: weak cation exchange
• Typical sample types: water, biological fluids
The Varian Bond Elut Cellulose column utilizes a pure microgranular cellulose powder that is packed between two 20 um polyethylene frits in an ultraclean 3 mL polypropylene extraction column. The unique rod-like shape and controlled particle size of this variety of Cellulose ensure that it is free-flowing when dry. In addition, the material is manufactured from high purity cotton with a very high a-cellulose content that ensures optimum column packing properties. Thus, high density, more uniform, smooth-packed column beds are achieved. In addition, the cellulose phase is very stable over a wide pH range and contains an extremely low metal content (Fe and Cu content less than 5 ppm). The combination of surface area and polymeric structure results in a sorbent with excellent capacity.
The cellulose media contains numerous hydroxyl groups. Because of its polar nature, it is able to accept high loading of many polar substances from aqueous and organic phases. The free hydroxyl groups' binding properties are complemented by the presence of very small quantities of residual aldehydes, ketones and carboxyl groups. These weak groups add reducing and ion-exchange properties.
This microgranular cellulose support has been utilized for large professional scale bioprocessing as well as a prefilter for suspended matter (i.e. cell debris and suspended fats), as a prefractionation step prior to reverse phase HPLC, for separation of biomolecules, and as an affinity chromatography matrix.
For assistance selecting the best sorbent for your application, please see the Sorbent Selection Guide on pages 5-11, or visit www.varianinc.com and use our Applications Online Scanview database.
Bond Elut Straight Barrel Cartridges
q. m
S m m q.
in Q)
^_
CL
Bond Elut CBA carboxylic acid sorbent
CBA is a medium polarity sorbent based on carboxy propyl functionalized silica, exhibiting either polar or nonpolar interactions depending on the matrix or solvent environment. Its prime characteristic is its weak cation exchange properties. Because of its pKa value of 4.8, CBA does not require extreme basic conditions for elution that are required by other cation exchange sorbents. Above a pH of 4.8, the majority of functional groups carry a negative charge that can be used for retaining cationic compounds. Dropping the pH to 2.8 effectively neutralizes CBA, permitting the retained analytes to elute from the sorbent. For this reason, CBA is often the best choice for cation exchange, especially when dealing with very strong cations (i.e. high pKa cations). In addition, CBA shows a wider range of selectivity towards counter-ions than other cation exchange phases, enabling more options for elution.
For assistance selecting the best sorbent for your application, please see the Sorbent Selection Guide on pages 5-11, or visit www.varianinc.com and use our Applications Online Scanview database.
Bond Elut LRC Cartridges
Sorbent Mass (mg)
Volume (mL)
40 urn
120 um
Quantity (/Box)
100
10
12113011
14113011
50
500
10
12113037
14113037
50
Bond Elut Straight Barrel Cartridges
Sorbent Mass
Volume (mL)
40 um
120 um
Quantity (/Box)
50 mg
1
12102073
100
100 mg
1
12102011
14102011
100
3
12102097
50
200 mg
3
12102124
50
500 mg
3
12102038
14102038
50
1 g
6
12256009
14256009
30
2 g
12
12256058
20
Sorbent Mass (mg)
Volume (mL)
Part No.
Quantity (/Box)
300
3
12102095
500
Bond Elut Cartridges with Stainless Steel Frits
Sorbent Mass
(mg)
Volume (mL)
40 um
120 um
Quantity (/Box)
100
1
12124011
14124011
100
500
3
12124035
14124035
50
See All of Our Products, and Shop Online at www.varianinc.com
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-150
151-200
201-250
251-300
301-350
351-400
401-450
451-476
pdf-page pdf di En 2009-01-02-08