Selection Table for VAMP Protection Relays
VTEN008 / 16.10.2006
Protection and measurement
IEEE Device No.
Type of fault
Short circuit
IEC Symbol Protection function/measurement
50/51 3I > Three-phase non-directional overcurrent, low-set stage, definite or inverse time
x
x
x
x
x
x
x
x
x
x
x
x
x
x
50/51 3l >> Three-phase non-directional overcurrent, high-set stage, definite time
x
x
x
x
x
x
x
x
x
x
x
x
x
x
50/51 3l >>> Three-phase non-directional overcurrent, high-set stage, definite time
x
x
x
x
x
x
x
x
x
x
x
x
6I> Six-phase non-directional overcurrent, low-set stage, definite time
x
67 3l > —> Three-phase directional or non dir. o/c, low-set stage, definite or inverse time
x
x
x
x
x
x
67 3l >> —> Three-phase directional or non dir. o/c, high-set stage, definite or inverse time
x
x
x
x
x
x
67 3I >>> —> Three-phase directional or non dir. o/c, high-set stage
x
x
x
x
x
x
67 3I >>>> —> Three-phase directional or non dir. o/c, high-set stage
x
x
x
x
x
x
50N/51N l0 >/ SEF Non-directional earth-fault, low-set stage, sensitive, definite or inverse time
x
x
x
x
x
x
x
x
x
x
x
x
x
50N/51N l0 >> Non-directional earth-fault
x
x
x
x
x
x
x
x
x
x
x
x
x
x
50N/51N l0 >>> Non-directional earth-fault
x
50N/51N I02 >, I02>> Non-directional earth-fault, second Io input
x
x
x
x
x
x
x
x
x
x
x
I0>, I02> Non-directional earth-fault, separate inputs
x
67N or 50N/51N l0 > —> / SEF Directional or non dir. earth-fault, low-set stage, sensitive, definite or inverse time
x
x
x
x
x
x
x
x
x
x
67N or 50N/51N l0 >> —> Directional or non dir. earth-fault, high-set stage, definite or inverse time
x
x
x
x
x
x
x
x
x
x
67N l0 > —> / SEF Directional earth-fault, low-set stage, sensitive
x
59N U0> Residual overvoltage, low-set stage
x
x
x
x
x
x
x
x
x
x
x
59N U0>> Residual overvoltage, high-set stage
x
x
x
x
x
x
x
x
x
x
x
Earth-fault
49M 6 Three-phase thermal overload (motors & generators)
JL
JL
JL
JL
JL
JL
JL
JL
49F 6 Three-phase thermal overload (feeders & cables)
_
_
_
_
_
JL
_
JL
_
JL
_
JL
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
Overload
59 1U>/3U> One-/Three-phase overvoltage, low-set stage
3
3
3
3
3
3
3
3
59 1U>>/3U>> One-/Three-phase overvoltage, high-set stage
3
3
3
3
3
3
3
3
59 1U>>>/3U>>> One-/Three-phase overvoltage, stage
3
3
3
3
3
3
3
3
27 / 60 1 U</3U< One-/Three-phase undervoltage, low-set stage / VT fuse failure
3
3
3
3
3
3
3
3
27 1U<</3U<< One-/Three-phase undervoltage, high-set stage
3
3
3
3
3
3
3
3
27 1U<<</3U<<< One-/Three-phase undervoltage, instantaneous stage
3
3
3
3
3
3
3
Voltage
50ARC/50NARC 3 I> / I0>, L> Electrical arc protection stage, point sensors, Optional
x
x
x
x
x
x
x
x
x
x
x
x
x
x
50ARC/50NARC 3 I> / I0>, L> Electrical arc protection with point sensor slave
x
x
x
50ARC/50NARC 3 I> / I0>, L> Electrical arc protection with point, fiber or current sensors slave
x
Arc protection
79 O --> I Auto-reclosure
x
x
x
x
x
68 lf2 > Inrush detector / Second harmonic stage
x
x
x
x
x
x
x
x
x
x
x
46 I2/I1 > Phase unbalance / discontinuity "Broken conductor"
x
x
x
x
x
x
46 I2 > Phase unbalance
x
x
x
x
x
x
x
47 I2 >> Phase sequence / reversal
x
x
x
x
x
48 IST > Stall protection
x
x
x
x
x
x
37 3I< Loss of load / under current
x
x
x
x
x
x
x
x
x
x
x
87 3 d I> Three phase biased differential stage, low-set stage, 2nd harmonic blocking
x
87 3 d I>> Three phase differential stage, high-set stage
x
66 N> Too frequent starting
x
x
x
x
x
x
64F3 U0f3 > 100% stator earth fault protection
x
40 Q < Underexcitation protection
x
40 X<, X<< Loss of excitation
x
32 P<,P<< One-/Three-phase reverse power and underpower protection
T
3
24 Uf > Volts/hertz overexcitation protection
x
50BF CBFP Circuit breaker failure
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
81H/81L f ><, f >><< Overfrequency and underfrequency protection
x
x
x
x
x
x
x
x
81L f<, f<< Underfrequency protection
x
x
x
x
x
x
x
x
81R df/dt Rate of change of frequency (ROCOF) protection
x
21 Z<, Z<< Under-impedance protection
x
51V IV > Voltage restrained or controlled overcurrent, underimpedance
x
25 df,dv Synchrocheck
x
x
x
x
x
x
x
Short circuit fault location
x
x
x
x
x
x
x
8 Programmable stages
x
x
x
x
x
x
x
x
x
x
x
x
DR Disturbance recorder
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Other functions
Disturbance recording
Type of measurement
Primary current
3I Three-phase current
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
3 d I > Three-phase differential current
x
l0 Neutral current
x
x
x
x
x
x
x
x
x
x
x
x
x
x
I2 Current unbalance
x
x
x
x
x
x
x
x
x
x
x
x
x
IL Average and maximum demand current
x
x
x
x
x
x
x
x
x
x
x
x
U/3U One-/Three-phase and line voltages
T
3
~3~
3
3
3
1
3
3
~3~
3
"3"
3
U0 Residual voltage
x
x
x
x
x
x
x
x
x
x
x
U2 Voltage unbalance
x
x
x
x
x
x
x
Xfault Short-circuit fault reactance
x
x
x
x
x
x
f System frequency
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
P Active power
x
x
x
m
x
x
x
x
x
Q Reactive power
(x)
x
x
x
(x)
x
x
x
x
x
S Apparent power
(x)
x
x
x
(x)
x
x
x
x
x
E+, E- Active Energy, exported / imported
(x)
x
x
x
(x)
x
x
x
x
Eq+, Eq- Reactive Energy, exported / imported
(x)
x
x
x
(x)
x
x
x
x
PF Power factor
m
x
x
x
(x)
x
x
x
x
x
I 2nd to 15th and THD of phase currents
x
x
x
x
x
x
x
x
x
x
x
x
U 2nd to 15th and THD of measured voltages
x
x
x
x
x
x
x
U Voltage sags / swells
x
x
x
x
x
x
AO Any measured or calculated value, freely scalable
x
x
x
AO Any measured or calculated value, freely scalable, Optional
x
x
x
x
x
Primary voltage
Short-circuit fault reactance
Frequency
Power
Energy
Power factor Harmonics
Voltage sags / swells Analog mA output, 1 channel Analog mA output, 4 channels
Control
Output relays
Object status indication Local and remote control Interlocking and logic
Condition monitoring
Trip circuit
CT Supervision VT Supervision CB Wear
(x) : Based on one-phase voltage measurement
Number of trip relays
2
2
2
2
2
4
8
2
2
2
2
2
4
8
2
2
Number of alarm relays
3
3
3
5
5
5
5
3
3
5
5
5
5
5
5
5
Single line diagram, 8 objects
x
x
x
x
x
x
x
x
x
Number of controllable objects
~5~
~6~
6
6
6
5
6
~6~
6
6
6
Configurable
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
TCS Trip Circuit Supervision
TCS Trip Circuit Supervision with 4xDI for T5...T8
CT Supervision VT Supervision Breaker wear
Communication
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
IEC 60870-5-103 Modbus TCP Modbus RTU
Profibus DP
DNP 3.0
SPA-bus communication Man-Machine-Communication, display Man-Machine-Communication, PC
General functions
Selfsupervision
Annunciating, event generating and value recording Measurement and parameter display Real time clock
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Year, month, day, hour, minutes, seconds, milliseconds
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

pageCatalog pdf di En 2012-06-22-01