You may also be interested in
Measuring device, Humidity indicator, Data-logger, Humidity data-logger, Sensor
Text version of the page
Untitled
table.main {}
tr.row {}
td.cell {}
div.block {}
div.paragraph {}
.font0 { font:4.00pt "Arial", sans-serif; }
.font1 { font:5.00pt "Arial", sans-serif; }
.font2 { font:7.00pt "Arial", sans-serif; }
.font3 { font:9.00pt "Arial", sans-serif; }
.font4 { font:21.00pt "Arial", sans-serif; }
.font5 { font:7.00pt "Palatino Linotype", serif; }
Technical data
Wind
Air température
SPEED range
response time accuracy 0 ... 35 m/s
35 m/s ... 60 m/s
output resolutions and
units DIRECTION
azimuth
response time
accuracy output resolution and unit
0 ... 60 m/s 250 ms
±0.3 m/s or ±3%, whichever is greater
±5%
0.1 m/s, 0.1km/h, 0.1 mph, 0.1 knots
0 ... 360° 250 ms
±3° 1°
Range -52 ... +60 °C (-60 ... +140 °F)
Accuracy for sensor at +20 °C ±0.3 °C (±0.5 °F)
Accuracy over temperature range (see graph below)
0.6
■0.7
40
30
Output resolutions and units
0.1 °C, 0.1 °F
Liquid précipitation
cumulative accumulation after the latest automatic or manual reset
0.01 mm, 0.001 inches
5%*
counting each ten-second increment whenever water droplet is detected
10 s
one-minute running average in ten-second steps 0 ... 200 mm/h (broader range with reduced accuracy)
0.1 mm/h, 0.01 inches/h cumulative amount of hits against the collecting surface
0.1 hits/cm2, 0.01 hits/in2, 1 hits counting each ten-second increment whenever hailstone is detected
10 s
one-minute running average in ten-second steps 0.1 hits/cm2h, 1 hits/in2h,
1 hits/h
Barometric pressure
RAINFALL
output resolutions and units
accuracy RAINFALL DURATION
output resolution and unit
RAIN INTENSITY range
output resolutions and units
HAIL
output resolutions and units
HAIL DURATION
output resolution and unit
HAIL INTENSITY
output resolutions and units
Range Accuracy
Output resolutions and units
600 ... 1100 hPa ±0.5 hPa at 0 ... +30 °C (+32 ... +86 °F) ±1 hPa at -52 ... +60 °C (-60 ... +140 °F) 0.1 hPa, 10 Pa, 0.0001 bar, _0.1 mmHg, 0.01 inHg
Relative humidity
0 ... 100 %RH
±3 %RH within 0 ... 90 %RH ±5 %RH within 90 ... 100 %RH
0.1 %RH
Range Accuracy
Output resolution and unit
General
-52 ... +60 °C (-60 ... +140 °F) -60 ... +70 °C (-76 ... +158 °F) 5 ... 32 VDC 3 mA at 12 VDC (with defaults) 5 ... 32 VDC (or AC, max. 30 VRMS) SD1-12, RS-232, RS-485, RS-422, USB connection, 650 g (1.43 lb)
1P65 1P66
Operating temperature Storage temperature Operating voltage Typical power consumption Heating voltage Serial data interface
Weigth Housing
Housing with mounting kit
* Due to the nature of the phenomenon, deviations caused by spatial variations may exist in precipitation readings, especially in a short time scale. The accuracy specification does not include possible wind induced errors.
Electromagnetic compatibility
Complies with EMC standard EN61326-1; Industrial Environment 1EC standards
1EC 60945/61000-4-2 ... 61000-4-6
For more information, visit www.vaisala.com or contact us at sales@vaisala.com
Ref. B210417EN-E ©Vaisala 2009
This material is subject to copyright protection, with al copyrights retained by Vaisala and its individual partners. Al rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice.
|
|