Catalog excerpts
www.vaisala.com HM34 Pocket Size Relative Humidity Meter The Vaisala HUMICAP® Hand-Held Humidity and Temperature Meter HM34 provides a fast and convenient way to accurately spot-check relative humidity and temperature. Fast and easy-to-use In measurement mode, the extendable probe just slides out. Normally, measurement takes only a few seconds. The HM34 meter includes a HOLD button which allows the user to retain an RH or T measurement until it has been noted or recorded. The Vaisala HUMICAP® Hand-Held Humidity and Temperature Meter HM34 provides accurate spot checks of humidity and temperature. If no buttons are pressed for three minutes, the unit automatically switches itself off. This automatic POWER-OFF function prevents the possibility of accidental discharge of the HM34’s battery. After the measurement is completed, the probe is slid back into the meter casing. Between spot checks, the meter is normally stored in its carrying case. Features/Benefits Ideal for spot checking humidity levels Measurement range 0 ... 100 %RH Fast response with ±2% accuracy Temperature measurement range -20 ... +60 °C (-4 ... +140 °F) Lightweight, pocket-sized Extendable probe Automatic POWER-OFF Features/Benefits Incorporates Vaisala HUMICAP® Sensor that provides high accuracy, excellent long-term stability, neglible hysteresis, and insensitivity to dust and most chemicals Available in either °F or °C NIST traceable (certificate included) Each unit comes with a 9V battery, attached probe, 0.2 ìm protective membrane filter and a carrying case
Open the catalog to page 1Technical data Relative humidity Measurement range 0 ... 100 %RH Accuracy ±2% (0 ... 90 %RH) ±3% (90 ... 100 %RH) Resolution 0.1 %RH Temperature dependence ±0.04 %RH/°C Sensor type HUMICAP®H thin film capacitive sensor Response time (90%) 15 s with membrane filter 5 s with plastic grid General Display 3 1/2 digit LCD Hold function Push-button hold of displayed value Power supply 9 V battery Battery operation time 50 h Automatic POWER OFF after 3 minutes, unless HOLD is activated Operating temperature range -20 ... +60 °C (-4 ... +140 °F) Housing ABC plastic Sensor protection standard...
Open the catalog to page 2All VAISALA catalogs and technical brochures
-
OPT100 Optimus™ DGA Monitor
4 Pages
-
DMP6 Dew Point Probe
2 Pages
-
GMP252 Carbon Dioxide Probe
3 Pages
-
Vaisala weather radars
4 Pages
-
Weather Radar WRK200
3 Pages
-
Indigo 520 Transmitter
2 Pages
-
CO₂ Transmitter Series GM20
2 Pages
-
MGP261 Multigas Probe
2 Pages
-
GMP251 Carbon Dioxide Probe
3 Pages
-
Indigo 520 Transmitter
2 Pages
-
DL4000 Universal Data Logger
2 Pages
-
MMP8 Moisture in Oil Probe
2 Pages
-
TMP1 Temperature Probe
2 Pages