Vaisala CARBOCAP® Carbon Dioxide Probe GMP343 - VAISALA - #2

/ 2


catalogue search
P. 01
P. 02
Pages:


See other catalogues for VAISALA

Text version of the page
Untitled table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:21.00pt "Arial", sans-serif; } .font3 { font:33.00pt "Arial", sans-serif; } .font4 { font:4.00pt "Lucida Sans Unicode", sans-serif; } .font5 { font:7.00pt "Palatino Linotype", serif; } .font6 { font:9.00pt "Palatino Linotype", serif; } Technical data PRESSURE Inputs and outputs CO, range options 0 ... 1000 ppm 0 ... 2000 - 2 % Pressure (hPa) Accuracy (% of reading) 900 ... 1050 ±0.5 ±1 700 ... 1300 ±1 ±2 Operating voltage Power consumption without optics heating with optics heating ANALOG OUTPUTS Current output range resolution max. load Voltage output range resolution min. load DIGITAL OUTPUTS 11 ... 36 VDC <1 W <3.5 W Integrated pressure sensor is not included in GMP343 Long term stability see graph below easy <±2 % of reading / year 4 ... 20 mA 14 bits 800 Ohm @ 24 VDC, 150 Ohm @ 10 VDC 0 ... 2.5 V, 0 ... 5 V 14 bits (13 bits with 0 ... 2.5 V) 5 kOhm RS485, RS232 moderate harsh <±2 % of reading / 6 months <±2 % of reading / 3 months GMP343 OPERATING CONDITIONS 1 Materials Response time (90 %) Housing Filter cover anodized aluminium PC DIFFUSION MODEL Filter attached Averaging (s) Response (s) IP classification Housing (cable attached) <1 W 1P67 Yes 0 75 Diffusion filter (weather protection) 1P65 Yes 30 82 Diffusion filter (sintered PTFE) Cable connector type 1P66 8-pin M12 No 0 <2 No 30 30 Weight (probe only) 360 g FLOW-THROUGH MODEL Gas flow (l/min) Averaging (s) Response (s) 0.3 0 26 Options and accessories 0.3 1 0 30 A 44 Q Wall mount bracket GMP343BRACKET 1.2 1.2 0 30 8 23 Mounting flange GMP343FLANGE Warm-up time full accuracy ±0.5 % full accuracy 10 min 30 min Standard diffusion filter (weather protection, 1P65) +filter cover Diffusion filter (sintered PTFE filter, 1P66) + filter cover GMP343F1LTER 215521 Operating Environment Calibration adapter (for the diffusion model) GMP343ADAPTER Temperature Junction box JUNCT1ONBOX-8 operating -40 ... +60 °C (-40 ...+140 °F) Probe cables storage -40 ... +70 °C (-40 ... 158 °F) 2m GMP343Z200SP Humidity see graph 'GMP343 Operating Conditions' 6m GMP343Z600SP Pressure 10m GMP343Z1000SP compensated range 700 ... 1300 hPa PC connection cable, 2m 213379 operating <5 bar M170 connection cable, 2m DRW216050SP Gas flow for flow-through model 0 ... 10 liters/min USB adapter (USB-D9 Serial connection cable) 219686 Electromagnetic compatibility EN61326, Generic Soil adapter kit for horizontal positioning 215519 Environment Soil adapter kit for vertical positioning 215520 For more information, visit www.vaisala.com or contact us at sales@vaisala.com Ref. B210688EN-B ©Vaisala 2009 This material is subject to copyright protection, with al copyrights retained by Vaisala and its individual partners. Al rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice.

pageCatalog pdf di En 2012-06-22-01