HM70
humidity dewpoint
ïechnical Data
HMP75, HMP76 and HMP77 probes Measured variables_
Relative humidity
Measurement range 0 ... 100 %RH
Accuracy (including nonlinearity, hysteresis and repeatability)
at +15 ... +25 °C (+59 ... +77 °F) ±1 %RH (0 ... 90 %RH)
±1.7 %RH (90 ... 100 %RH) at -20 ... +40 °C (-4 ... +104 °F) ±(1.0 + 0.008 x reading) %RH
at -40 ... +180 °C (-40 ... +356 °F) ±(1.5 + 0.015 x reading) %RH Factory calibration uncertainty (+20 °C / +68 °F)
±0.6 %RH (0 ... 40 %RH) ±1.0 %RH (40 ... 97 %RH) (Defined as ±2 standard deviation limits.) Response time (90%) at +20 °C (+68 °F) in still air
HMP75 (with standard plastic grid) 17 s
HMP76 (with standard sintered bronze fllter) 60 s
HMP77 (with standard plastic grid and stainless steel netting) 50 s
Sensor HUMICAP® 180R
HUMICAP® 180RC (chemical purge, sensor preheat) Typical long-term stability better than 1 %RH / year
Température Measurement range
MI70 measurement indicator Indicator general
Menu languages Display
Max. no of probes Power supply
English, Chinese, French, Spanish, German, Russian, Japanese, Swedish, Finnish LCD with backlight, graphic trend display of any parameter, character height up to 16 mm
2
Rechargeable NiMH battery pack with AC-adapter
or 4xAA-size alkalines, type IEC LR6 Analog output 0 ... 1 VDC
Output resolution 0.6 mV
PC interface MI70 Link software with USB or serial port cable
Data logging capacity 2700 points
Alarm audible alarm function
Operating temperature range -10 ... +40 °C (+14 ... +104 °F)
Operating humidity range non-condensing
Housing classiication IP54
Weight 400 g
Battery operation time
Continuous use 48 h typical at +20 °C (+68 F)
Data logging use up to a month, depending on logging interval
Electromagnetic compatibility Complies with EMC standard
MI70 indicator + probe = HM70
Aeeessories
Carrying cases
for MI70 and HMP75/77 probe
MI70CASE
for MI70 and HMP75/76 probe
MI70CASE2
Transmitter connection cables for
HMP230 Series
27159ZZ
HMT330 & HMT100 Series
211339
HM60/70/140 Series
HMA6070
HM20/30/130 Series
HMA2030
MI70 Link software with USB cable
219687
MI70 Link software with serial port cable
MI70LINK
Analog output cable
27168ZZ
Sensor protection
HMP75
Plastic PC grid (HMP75 standard)
6221
Membrane ilter
10159HM
Sintered bronze ilter
DRW212987SP
HMP76/77
Plastic PPS grid
DRW010276SP
Sintered stainless steel filter
HM47280SP
Sintered bronze ilter (HMP76 standard)
DRW212987SP
PPS grid with SS netting (HMP77 standard)
DRW010281SP
Dimensions
Dimensions in mm (inches)
HMP75 HMP76
short time
HMP77
Accuracy at +20 °C (+68 °F) Accuracy over temperature range
-20 ... +60 °C (-4 ... +140 °F) -50 ... +120 °C (-58 ... +248 f) -50 ... +180 °C (-58 ... +356 °f)
-70 ... +180 °C (-94 ... +356 °F) ±0.2 °C (±0.36 °F)
(see graph)
A x
0.7,0.6 0.5 0.4 0.3 0.2 0.1
0
-0.1 -0.2 -0.3 -0.4 -0.5
-0.6 -0.7
•c
-80 -60
-40 -20
0
20
40
60
80
100 120
140 160 180
Temperature sensor
Pt100 IEC751 1/3 class B
Calculated variables (typical ranges)_
Dewpoint temperature -20 ... +100 °C (-4 ... +212 °F)
Mixing ratio 0 ... 600 g/kg dry air
Absolute humidity 0 ... 600 g/m3
Wet bulb temperature 0 ... 100 °C (+32 ... +212 °F)
Enthalpy 0 ... 160 kJ/g
Water vapor pressure 0 ... 1000 hPa
The accuracies of these calculated variables are limited by the accuracies of the measured variables on which they are based, namely RH and T. The RH and T accuracies are stated above under Measured Variables.
HMP76
HMP77
HMP75
0 12(0.47)
0 12 (0.47)
Probe general
Operating temperature range for electronics
Housing classification Housing material Probe material
Cable length between probe and indicator Weight
HMP75 HMP76
HMP77_
-40 ... +60 °C
(-40 ... +140 °F) IP65 (NEMA 4)
ABS/PC blend
Stainless steel (AISI316L) 1.9 m
250 g 350 g
500 g
HUMICAP® is a registered trademark of Vaisala. Specifications subject to change without prior notice. © Vaisala Oyj
Vaisala Instruments Catalog 2009
Ref. B210768EN rev. A
39
|
|