Insulated Conduxtor System U10 - VAHLE - #11

/ 16


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
Pages:


See other catalogues for VAHLE
You may also be interested in

Busbar, Crane, Cable trolley, Gantry, Cable reel


Text version of the page
COMPONENTS /È*.
Connecting cable, high flexible
for collectors, feed terminals, transfer guides and isolating assemblies (for collector KDS, connecting cable WFLA 2.5)
Plug only
FLA (FKA)
Type
for cable 0 mnv
Cat.-No.
FH 2.5
2.5
165 120
FH 4
4.0
165121
WFH 2.5
2.5
168 109
0.5 m long with quick connect plug 6.3 x 0,8 Longer cable available.
1 m long with quick connect plug 6,3 x 0,8 Longer cable available.
Simple insulation (not for collectors)
Heavy double insulation
type
cross section mm-
A
0 mm
Weight
m
Cat phase black
-No.
ground greervyellow
FLA 1.5
1.5
4.0
0.014
166 555
166 556
FLA 2.5
2.5
4.4
0.080
165 049
165 050
FLA 4
4.0
6.4
0.100
165 051
165 052
WFLA 2.5
2.5
4.4
0.080
168107
168106
Type
cross section
mm1
A 0 mm
Weight
kg
Ci
phase black
rt.-No.
ground green/yellow
FKA 1.5
1.5
3.0
0.014
166 557
166 558
FKA 2.5
2.5
3.5
0.026
166 238
166 239
FKA 4
4.0
5.0
0.040
166 240
166 241
FKA 6
6.0
6.0
0.060
166 242
166 243
Terminal box AKE
for feeding and sectionalizing
(max. 7 terminals 6 mm' plus 2 idem for ground)
Terminal box AKB
for process-zones control
Type
Weight kg
Cat.-No.
AKE
0.445
169 462
Type
Weight kg
Cat.-No.
AKB
0,469
169 481
The brush wear indicator will automatically check the brush wear and indicate necessary brush replacement. A continuous axle connected to an enclosed microswitch is equipped with steel feeler pins, arranged between the conductor bars and adjustable to the maximum brush wear level.
Current collectors with worn down brushes will depress the feeler pins, rotating the axle and activating the microswitch to promote a signal or a control function to route for example a carrier thru a track switch into a maintenance bay area.
Track- and vehicle-drawings will be useful for a smooth coordi­nation. Opening in the track, length: 120 mm, height: 50 mm.
Brush wear indicator lor U 10 with microswitch
Brush wear indicator KVT 10 N
Type
poles
dim. A
Weight kg
Cat.-NO.
Cat.-No. high temp.
•V::: ..d
KVT 10 N- 4
4
60
0.809
166 957
142 452
KVT 10 N- 5
5
88
0.957
167 440
142 453
KVT 10 N- 6
6
88
1.104
166 895
142 454
KVT 10 N- 7
7
116
1.252
167 441
142 455
KVT 10 N- 8
8
116
1.400
166 896
142 456
KVT 10 N- 9
9
144
1.546
167 442
142 457
KVT 10 N-10
10
144
1.694
166 897
142 468
KVT10N-11
11
172
1.842
167 443
142 459
KVT 10N-12
12
172
1.990
167 444
142 460
Shown is KVT 10 N-10
11