Text version of the page
ACCESSORIES FOR U 25
1912 Contact Grease
for joints and feeds 421 g for approx. 1000 jointsCat.-No.120 01720 g for approx. 40 jointsCat.-No. 120016 >
Isolating sections
3030 A max. 200 max. 200max. 200max. 200min. 200 Feed Typ M =Factory assembled according to system layoutTyp L=Loose c/w two locking pins 3 x 20.Consider one extra hanger. Distance from center of isolating section 200 m.Conductors, hangers and feeds are to be ordered separately.
Type M=factory assembledType L=LooseWidth: 40 mm >
30stromlos w/o cond. TypeWeight kgCat.-No. IT/U 25/30 M 0.015170 070 IT/U 25/30 L 0.015170 071 In order to avoid voltage bridging and for clearing of maintenance, control and live areas use two isolating sections.
Distance A depends on collector type and length of brake path of machinery. >
End caps Insulated hangers
(1) c/w locking pin 3 x 20 >
M 8 26,5 max. 10 2127 30 TypeWeight kgCat.-No. TypeWeight kgCat.-No. UK 25-M 0.005170 793 UA 25 0.040170 761 UK 25-L 0.005170 013 UA 25 K 4 >
(2) 0.040170 762 >
Insulators
(1) Rail holders
to be used with insulator >
M 8 8 14,5 27 30 cantilever = 3000 Ncreapage distance = 60 mm Width: 40 mm >
TypeWeight kgCat.-No. TypeWeight kgCat.-No. GH 40-M 8 0.100170 146 UAK 25 0.023170 868 GH 40-M 8 K 4 >
(2) 0.100170 148 UAK 25 K 4 >
(2) 0.023170 869 >
(1) Use flat washers (see page 32) on both sides of brackets with slotted holes. (2) with stainless steel hardware 25