Insulated conductor system - VAHLE - #23

/ 48


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
P. 23
P. 24
P. 25
P. 26
P. 27
P. 28
P. 29
P. 30
P. 31
P. 32
P. 33
P. 34
P. 35
P. 36
P. 37
P. 38
P. 39
P. 40
P. 41
P. 42
P. 43
P. 44
P. 45
P. 46
P. 47
P. 48
Pages:


See other catalogues for VAHLE
You may also be interested in

Tensioner, Cable trolley, Busbar, Crane, Reel


Text version of the page
Support spacing:

Insulated conductor system - 19699 INSULATED CONDUCTORS U 25

- for straight runs &for inside & outside curves:1500 mm- horizontal curves: up to R
1912 1923 Conductor code: U= unipole insulated conductor 25= shroud size 50-125= conductor cross sectional area(mm
122715 U 25 C
2 )C= copper conductor AE= Aluminium conductor contact surface stainless steel.
H = 10 m
(2) :750 mm- horizontal curves:above R
H = 10 m
(2) :1500 mm Length:
78R RadiusHorizontal curve 6 m is standard length, shorter lengths are available Curves:
H Conductor spacing: factory prepared from R = 800 mm or in the field horizontal curves:from R = 7000 mm inside & outside curves:from R = 2500 mmAE-conductor on request.Heating system available on request. on standard hangers 50 – 80 mm on compact hangers 50 mmChemical and electrical propertiesand temperature resistance see page 4.
23 19 12 U 25 AE
27 15 8 Type U 25/50 CU 25/75 CU 25/100 CU 25/125 CU 25/90 AEU 25/125 AE Weight kg/m0,5500,7401,0001,2600,4500,540 Standard shroud, color green Cat.-No. phase
(2) 171 02 •171 03 •171 04 •171 20 •171 24 •171 28 •Cat.-No. PE
(2) 171 12 •171 13 •171 14 •171 21 •171 25 •171 29 • High temperature shroud, color grey Cat.-No. phase
(2) 171 07 •171 08 •171 09 •171 22 •171 26 •171 30 • Cat.-No. PE
(2) 171 17 •171 18 •171 19 •171 23 •171 27 •171 31 •

Engineering data

(3) Ohm/1000 mbased on 50 HZ & conductor spacing50 mm 80 mmCross sectional areamm Conductor RailTyp2Leakagedistance of coversmmmax.voltageVmax.Amp. capacityA at 35 °CResistanceOhm/1000 mImpedance 2 U 25/50 C 505310002000,3510,3780,388 U 25/75 C 755310003000,2390,2690,283 U 25/100 C 1005310004000,1800,2190,236 U 25/125 C 1255310004500,1400,1880,208 U 25/ 90 AE
(4) 905310002300,3470,3690,380 U 25/125 AE
(4) 1255310003200,2400,2710,285

Selection of conductors

in accordance to ampere load and environmental conditions. U 25 / … C copper conductors for power and control system application. U 25 / … AE Aluminium conductor and stainless steel conductor surface for power and control system
27

Bolted joint splices

Typ UV 25, UV 25 K 4, UV 25 AE and UV 25 AE K 4 applicableas feed terminal, too.
50 M 6 21 160 TypeWeight kgCat.-No. connectin cable max. mm 2 UV 25 2 x 160,190170 595 UV 25 K 4
(5) 2 x 160,190170 596 UV 25 AE 2 x 160,150170 960
4545 UV 25 AE K 4
(5) 2 x 160,150170 961 Are adequate fo feed terminal UE
(1) Add last number (1, 2, 3, 4, 5 or 6 m length suffix) in accordance to bars required. (1) recommendation

23


pageCatalog pdf di En 2012-02-07-15